Your browser doesn't support javascript.
loading
Direct Injection Liquid Chromatography High-Resolution Mass Spectrometry for Determination of Primary and Secondary Terrestrial and Marine Biomarkers in Ice Cores.
King, Amy C F; Giorio, Chiara; Wolff, Eric; Thomas, Elizabeth; Roverso, Marco; Schwikowski, Margit; Tapparo, Andrea; Bogialli, Sara; Kalberer, Markus.
Afiliação
  • King ACF; British Antarctic Survey , High Cross, Madingley Road , Cambridge CB3 0ET , United Kingdom.
  • Giorio C; Department of Chemistry , University of Cambridge , Lensfield Road , Cambridge CB2 1EW , United Kingdom.
  • Wolff E; Department of Chemistry , University of Cambridge , Lensfield Road , Cambridge CB2 1EW , United Kingdom.
  • Thomas E; Dipartimento di Scienze Chimiche , Università degli Studi di Padova , Via Marzolo 1 , Padova 35131 , Italy.
  • Roverso M; Department of Earth Sciences , University of Cambridge , Downing Street , Cambridge CB2 3EQ , United Kingdom.
  • Schwikowski M; British Antarctic Survey , High Cross, Madingley Road , Cambridge CB3 0ET , United Kingdom.
  • Tapparo A; Dipartimento di Scienze Chimiche , Università degli Studi di Padova , Via Marzolo 1 , Padova 35131 , Italy.
  • Bogialli S; Paul Scherrer Institut , OFLB/109, Villigen PSI 5232 , Switzerland.
  • Kalberer M; Dipartimento di Scienze Chimiche , Università degli Studi di Padova , Via Marzolo 1 , Padova 35131 , Italy.
Anal Chem ; 91(8): 5051-5057, 2019 04 16.
Article em En | MEDLINE | ID: mdl-30893554
ABSTRACT
Many atmospheric organic compounds are long-lived enough to be transported from their sources to polar regions and high mountain environments where they can be trapped in ice archives. While inorganic components in ice archives have been studied extensively to identify past climate changes, organic compounds have rarely been used to assess paleo-environmental changes, mainly due to the lack of suitable analytical methods. This study presents a new method of direct injection high performance liquid chromatography-mass spectrometry (HPLC-MS) analysis, without the need of preconcentrating the melted ice, for the determination of a series of novel biomarkers in ice core samples indicative of primary and secondary terrestrial and marine organic aerosol sources. Eliminating a preconcentration step reduces contamination potential and decreases the required sample volume thus allowing a higher time resolution in the archives. The method is characterized by limits of detection (LODs) in the range of 0.01-15 ppb, depending on the analyte, and accuracy evaluated through an interlaboratory comparison. We find that many components in secondary organic aerosols (SOAs) are clearly detectable at concentrations comparable to those previously observed in replicate preconcentrated ice samples from the Belukha glacier, Russian Altai Mountains. Some compounds with low recoveries in the preconcentration steps are now detectable in samples with this new direct injection method significantly increasing the range of environmental processes and sources that become accessible for paleo-climate studies.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Biomarcadores / Monitoramento Ambiental / Cromatografia Líquida de Alta Pressão / Limite de Detecção / Gelo Idioma: En Revista: Anal Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Biomarcadores / Monitoramento Ambiental / Cromatografia Líquida de Alta Pressão / Limite de Detecção / Gelo Idioma: En Revista: Anal Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Reino Unido