Your browser doesn't support javascript.
loading
Quantitative Determination of Acetamiprid in Pollen Based on a Sensitive Enzyme-Linked Immunosorbent Assay.
Fang, Qingkui; Zu, Quan; Hua, Xiude; Lv, Pei; Lin, Wanwen; Zhou, Dahe; Xu, Zihan; Fan, Jiarui; Li, Xiaohan; Cao, Haiqun.
Afiliação
  • Fang Q; School of Plant Protection, Anhui Agricultural University, Hefei 230036, China. qkfang@163.com.
  • Zu Q; Key Laboratory of Biology and Sustainable Management of Plant Diseases and Pests of Anhui Higher Education Institutes, Anhui Agricultural University, Hefei 230036, China. qkfang@163.com.
  • Hua X; School of Plant Protection, Anhui Agricultural University, Hefei 230036, China. zuquan06053122@163.com.
  • Lv P; Key Laboratory of Biology and Sustainable Management of Plant Diseases and Pests of Anhui Higher Education Institutes, Anhui Agricultural University, Hefei 230036, China. zuquan06053122@163.com.
  • Lin W; College of Plant Protection, Nanjing Agricultural University, Nanjing 210095, China. huaxiude@njau.edu.cn.
  • Zhou D; School of Resource & Environment, Anhui Agricultural University, Hefei 230036, China. lvpei@ahau.edu.cn.
  • Xu Z; School of Plant Protection, Anhui Agricultural University, Hefei 230036, China. mei.mei906888037@163.com.
  • Fan J; School of Plant Protection, Anhui Agricultural University, Hefei 230036, China. 17352900322@163.com.
  • Li X; School of Plant Protection, Anhui Agricultural University, Hefei 230036, China. zhmirror03@sina.com.
  • Cao H; School of Plant Protection, Anhui Agricultural University, Hefei 230036, China. 15156879285@163.com.
Molecules ; 24(7)2019 Apr 01.
Article em En | MEDLINE | ID: mdl-30939790
ABSTRACT
A sensitive biotinylated indirect competitive enzyme-linked immunosorbent assay (Bic-ELISA) was developed to detect acetamiprid pesticides in pollen, based on the heterogeneous coating antigen and biotinylated anti-acetamiprid monoclonal antibody. Under optimized experimental conditions, the detection limit for the Bic-ELISA was 0.17 ng/mL and the linear range was 0.25⁻25 ng/mL. The cross-reactivities could be regarded as negligible for the biotinylated antibodies with their analogues except for thiacloprid (1.66%). Analyte recoveries for extracts of spiked pollen (camellia pollen, lotus pollen, rape pollen) ranged from 81.1% to 108.0%, with intra-day relative standard deviations (RSDs) of 4.8% to 10.9%, and the average reproducibility was 85.4% to 110.9% with inter-assay and inter-assay RSDs of 6.1% to 11.7%. The results of Bic-ELISA methods for the Taobao's website samples were largely consistent with HPLC-MS/MS. Therefore, the established Bic-ELISA methods would be conducive to the monitoring of acetamiprid in pollen.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pólen / Ensaio de Imunoadsorção Enzimática / Camellia / Lotus / Neonicotinoides / Anticorpos Monoclonais Tipo de estudo: Diagnostic_studies Idioma: En Revista: Molecules Assunto da revista: BIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pólen / Ensaio de Imunoadsorção Enzimática / Camellia / Lotus / Neonicotinoides / Anticorpos Monoclonais Tipo de estudo: Diagnostic_studies Idioma: En Revista: Molecules Assunto da revista: BIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China