Your browser doesn't support javascript.
loading
A sensitive quantification approach for detection of HETE-CP adduct after benzyl chloroformate derivatization using ultra-high-pressure liquid chromatography tandem mass spectrometry.
Chen, Bo; Yu, Hui-Lan; Liu, Shi-Lei; Liu, Chang-Cai; Liang, Long-Hui; Li, Xin-Hai; Li, Xiao-Sen; Wu, Ji-Na; Yang, Yang.
Afiliação
  • Chen B; State Key Laboratory of NBC Protection for Civilian, Beijing, 102205, China.
  • Yu HL; Laboratory of Analytical Chemistry, Research Institute of Chemical Defence, Beijing, 102205, China.
  • Liu SL; State Key Laboratory of NBC Protection for Civilian, Beijing, 102205, China. yuhuilan1@163.com.
  • Liu CC; Laboratory of Analytical Chemistry, Research Institute of Chemical Defence, Beijing, 102205, China. yuhuilan1@163.com.
  • Liang LH; State Key Laboratory of NBC Protection for Civilian, Beijing, 102205, China. liu_shilei@lacricd.com.
  • Li XH; Laboratory of Analytical Chemistry, Research Institute of Chemical Defence, Beijing, 102205, China. liu_shilei@lacricd.com.
  • Li XS; State Key Laboratory of NBC Protection for Civilian, Beijing, 102205, China.
  • Wu JN; Laboratory of Analytical Chemistry, Research Institute of Chemical Defence, Beijing, 102205, China.
  • Yang Y; State Key Laboratory of NBC Protection for Civilian, Beijing, 102205, China.
Anal Bioanal Chem ; 411(15): 3405-3415, 2019 Jun.
Article em En | MEDLINE | ID: mdl-31011788
ABSTRACT
Sulfur mustard (HD) reacts with human serum albumin (HSA) at Cys34 and produces a long-term biomarker of HD exposure. Here, we present a novel, sensitive, and convenient method for quantification of HD exposure by detection of HD-HSA adducts using pronase digestion, benzyl chloroformate (Cbz-Cl) derivatization, and ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). The HSA in HD-exposed plasma in vitro was precipitated with acetone and digested (2 h, 50 °C) with pronase to form the alkylated dipeptide, S-hydroxyethylthioethyl-CysPro (HETE-CP). The HETE-CP adduct was derivatized with Cbz-Cl to generate N-carbobenzoxy HETE-CP (HETE-C(Cbz)P). The derivatized product was analyzed by UHPLC-MS/MS. HD surrogate, 2-chloroethyl ethyl sulfide (2-CEES), was introduced as a non-isotope internal standard (ISTD) instead of traditional d8-HD for quantification. The method was found to be linear between 1.00 and 200 ng/mL HD exposure (R2 > 0.998) with precision of ≤ 9.0% relative standard deviation (RSD) and accuracy ranged between 97.1 and 111%. The limit of detection (LOD) is 0.500 ng/mL (S/N~5), over 15 times lower than that of the previous method (7.95 ng/mL). Time-consuming affinity purification or solid phase extraction (SPE) is not needed in the experiment and the operation takes less than 5 h. This study provides a new strategy and useful tool for retrospective analysis of HD exposure by HETE-CP biomarker detection. Graphical abstract Flow diagram for quantification of sulfur mustard exposure by detection of HETE-CP dipeptide adduct after benzyl chloroformate derivatization using ultra-high-pressure liquid chromatography tandem mass spectrometry.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Substâncias para a Guerra Química / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem / Gás de Mostarda Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Substâncias para a Guerra Química / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem / Gás de Mostarda Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China