Your browser doesn't support javascript.
loading
Rapid and Sensitive Surface-enhanced Raman Spectroscopy Method for Determination of Ketamine in Urine.
Han, Si-Qin-Gao-Wa; Chen, Xinxuan; Zhang, Chen; Zhao, Hang; Lin, Shuang; Zhang, Yanhua; Hasi, Wu-Li-Ji.
Afiliação
  • Han SQ; National Key Laboratory of Science and Technology on Tunable Laser, Harbin Institute of Technology.
  • Chen X; Affiliated Hospital, Inner Mongolia University for the Nationalities.
  • Zhang C; National Key Laboratory of Science and Technology on Tunable Laser, Harbin Institute of Technology.
  • Zhao H; National Key Laboratory of Science and Technology on Tunable Laser, Harbin Institute of Technology.
  • Lin S; National Key Laboratory of Science and Technology on Tunable Laser, Harbin Institute of Technology.
  • Zhang Y; National Key Laboratory of Science and Technology on Tunable Laser, Harbin Institute of Technology.
  • Hasi WL; The Second Affiliated Hospital of Harbin Medical University.
Anal Sci ; 35(11): 1209-1213, 2019 Nov 10.
Article em En | MEDLINE | ID: mdl-31308298
Surface-enhanced Raman spectroscopy (SERS) has gradually proved to be a powerful tool with wide applications in various fields. Here, a simple and rapid SERS method was developed for the determination of ketamine in urine based on silver aggregates as a SERS substrate. Ketamine in urine were demonstrated by the SERS technique with silver sol aggregated by a 0.5 M NaBr solution. The limit of detection for ketamine in urine could be obtained as low as 7.5 ppm, and a linear relationship for ketamine in urine between the Raman intensity and the concentrations was achieved in the range from 7.5 to 150 ppm (R2 = 0.977). Additionally, the recovery of this method ranged from 95.7 to 104.9%, which laid a favorable foundation for the rapid and reliable quantitative detection of ketamine in urine. Therefore, this SERS approach with high sensitivity and simplicity has a great prospect for the real-world application of ketamine in urine.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Espectral Raman / Urinálise / Ketamina Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Anal Sci Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Espectral Raman / Urinálise / Ketamina Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Anal Sci Ano de publicação: 2019 Tipo de documento: Article