Longitudinal Analysis of Real-World Performance of an Implantable Continuous Glucose Sensor over Multiple Sensor Insertion and Removal Cycles.
Tweden, Katherine S; Deiss, Dorothee; Rastogi, Ravi; Addaguduru, Suresh; Kaufman, Francine R.
Afiliação
  • Tweden KS; Senseonics, Incorporated, Germantown, Maryland.
  • Deiss D; Center for Endocrinology and Diabetology, Medicover Berlin-Mitte, Berlin, Germany.
  • Rastogi R; Senseonics, Incorporated, Germantown, Maryland.
  • Addaguduru S; Senseonics, Incorporated, Germantown, Maryland.
  • Kaufman FR; Senseonics, Incorporated, Germantown, Maryland.
Diabetes Technol Ther ; 22(5): 422-427, 2020 05.
Article em En | MEDLINE | ID: mdl-31697182
ABSTRACT
The Eversense® Continuous Glucose Monitoring (CGM) System, with the first long-term, implantable glucose sensor, has been commercially available in Europe and South Africa since 2016 for adults with diabetes. The performance of the sensor over multiple, sequential 90- or 180-day cycles from either real-world experience or clinical studies has not been previously published. The Eversense Data Management System (DMS) was used to evaluate the accuracy of General Data Protection Regulation (GDPR)-compliant sensor glucose (SG) values against self-monitoring of blood glucose (SMBG) from June 2016 through August 2019 among patients with at least four sensor cycles from European and South African health care practices. Mean SG and associated measures of variability, glucose management indicator (GMI), and percent and time in various hypoglycemic, euglycemic, and hyperglycemic ranges were calculated for the 24-h time period over each cycle. In addition, transmitter wear time was evaluated across each sensor wear cycle. Among the 945 users included in the analysis, the mean absolute relative difference (standard deviation [SD]) using 152,206, 174,645, 206,024, and 172,587 calibration matched pairs against SMBG was 11.9% (3.6%), 11.5% (4.0%), 11.8% (4.7%), and 11.5% (4.1%) during the first four sensor cycles, respectively. Mean values of the CGM metrics over the first sensor cycle were 156.5 mg/dL for SG, 54.7 mg/dL for SD, 0.35 for coefficient of variation, and 7.04% for GMI. Percent SG at different glycemic ranges was as follows <54 mg/dL was 1.1% (16 min), <70 mg/dL was 4.6% (66 min), ≥70-180 mg/dL (time in range) was 64.5% (929 min), >180-250 mg/dL was 22.8% (328 min), and >250 mg/dL was 8.1% (117 min). The median transmitter wear time over the first cycle was 83.2%. CGM metrics and wear time were similar over the subsequent three cycles. This real-world evaluation of adult patients with diabetes using the Eversense CGM System in the home setting demonstrated that the implantable sensor provides consistent stable accuracy and CGM metrics over multiple, sequential sensor cycles with no indication of degradation of sensor performance.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glicemia / Sistemas de Infusão de Insulina / Automonitorização da Glicemia / Diabetes Mellitus Tipo 1 / Diabetes Mellitus Tipo 2 Tipo de estudo: Risk_factors_studies Limite: Humans Idioma: En Revista: Diabetes Technol Ther Assunto da revista: ENDOCRINOLOGIA / TERAPEUTICA Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glicemia / Sistemas de Infusão de Insulina / Automonitorização da Glicemia / Diabetes Mellitus Tipo 1 / Diabetes Mellitus Tipo 2 Tipo de estudo: Risk_factors_studies Limite: Humans Idioma: En Revista: Diabetes Technol Ther Assunto da revista: ENDOCRINOLOGIA / TERAPEUTICA Ano de publicação: 2020 Tipo de documento: Article