Your browser doesn't support javascript.
loading
Disposable chlorine dioxide wipes for high-level disinfection in the ENT department: A systematic review.
Tofanelli, Margherita; Capriotti, Vincenzo; Saraniti, Carmelo; Marcuzzo, Alberto Vito; Boscolo-Rizzo, Paolo; Tirelli, Giancarlo.
Afiliação
  • Tofanelli M; Department of Otorhinolaryngology and Head and Neck Surgery, University of Trieste, Cattinara Hospital, Strada di Fiume 447, 34149 Trieste, Italy.
  • Capriotti V; Department of Otorhinolaryngology and Head and Neck Surgery, University of Trieste, Cattinara Hospital, Strada di Fiume 447, 34149 Trieste, Italy. Electronic address: vince.capriotti@gmail.com.
  • Saraniti C; Department of Otorhinolaryngology and Head and Neck Surgery, University of Palermo, P. Giaccone Hospital, Via del Vespro 129, 90127 Palermo, Italy.
  • Marcuzzo AV; Department of Otorhinolaryngology and Head and Neck Surgery, University of Trieste, Cattinara Hospital, Strada di Fiume 447, 34149 Trieste, Italy.
  • Boscolo-Rizzo P; Department of Neurosciences, Section of Otolaryngology and Regional Centre for Head and Neck Cancer, University of Padova, Piazzale dell'Ospedale, 1, 31100 Treviso, TV, Italy.
  • Tirelli G; Department of Otorhinolaryngology and Head and Neck Surgery, University of Trieste, Cattinara Hospital, Strada di Fiume 447, 34149 Trieste, Italy.
Am J Otolaryngol ; 41(3): 102415, 2020.
Article em En | MEDLINE | ID: mdl-32059828
ABSTRACT

BACKGROUND:

Nasopharyngoscope reprocessing methods should be effective, rapid and reproducible with moderate cost. Tristel Trio Wipes system (TTWS) is a manual reprocessing method based on chlorine dioxide that has lately emerged in ENT department. This review aims to collect evidence on this system.

METHODS:

The PubMed, Web of Science and Cochrane Library databases were searched for all the studies on TTWS or one of its components. Data were grouped according to the study type.

RESULTS:

Ten articles were included in the review. TTWS ensured high-level disinfection in laboratory and clinical setting. Although the limitations of the manual systems, TTWS proved to be faster than automated endoscope reprocessing (AER) and safe for patients and health-care workers. TTWS represented cheaper system than AER or sheaths in low- and medium-volume centers.

CONCLUSION:

TTWS could be a valid, safe and fast HLD method for nasopharyngoscopes, with reasonable costs for medium-low reprocessing volumes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Otolaringologia / Óxidos / Desinfecção / Contaminação de Equipamentos / Compostos Clorados / Laringoscópios / Departamentos Hospitalares Tipo de estudo: Guideline / Systematic_reviews Idioma: En Revista: Am J Otolaryngol Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Otolaringologia / Óxidos / Desinfecção / Contaminação de Equipamentos / Compostos Clorados / Laringoscópios / Departamentos Hospitalares Tipo de estudo: Guideline / Systematic_reviews Idioma: En Revista: Am J Otolaryngol Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Itália