Your browser doesn't support javascript.
loading
High day-to-day repeatability of lower extremity muscle activation patterns and joint biomechanics of dual-belt treadmill gait: A reliability study in healthy young adults.
Rutherford, Derek James; Moyer, Rebecca; Baker, Matthew; Saleh, Sara.
Afiliação
  • Rutherford DJ; School of Physiotherapy, Faculty of Health, Dalhousie University, Halifax, NS, Canada; School of Biomedical Engineering, Faculty of Engineering, Dalhousie University, Halifax, NS, Canada. Electronic address: djr@dal.ca.
  • Moyer R; School of Physiotherapy, Faculty of Health, Dalhousie University, Halifax, NS, Canada. Electronic address: rebecca.moyer@dal.ca.
  • Baker M; School of Physiotherapy, Faculty of Health, Dalhousie University, Halifax, NS, Canada. Electronic address: mdbaker@dal.ca.
  • Saleh S; School of Physiotherapy, Faculty of Health, Dalhousie University, Halifax, NS, Canada.
J Electromyogr Kinesiol ; 51: 102401, 2020 Apr.
Article em En | MEDLINE | ID: mdl-32087511
ABSTRACT

PURPOSE:

The reliability of lower extremity muscle activation patterns has not been clearly studied in a dual-belt instrumented treadmill environment. The primary study objective was to quantify the day-to-day reliability of quadriceps, hamstrings, gastrocnemius and gluteus medius activation patterns in healthy young adult gait. Secondarily, the reliability of spatiotemporal, and knee/hip motion and moment-based gait outcomes was assessed. SCOPE 20 young adults were recruited and tested on two separate days. Using standardized procedures, participants were prepared for surface electromyography and lower extremity motion capture. All individuals walked on a dual-belt instrumented treadmill while muscle activation, segment motions and ground reaction forces were recorded. Sagittal plane motion and net external sagittal and frontal plane moments were calculated. Discrete biomechanical and muscle activation measures were calculated, and non-negative matrix factorization extracted amplitude and temporal muscle activation features. Intraclass Correlation Coefficients, Standard Error of Measurement and Minimum Detectable Change were calculated.

CONCLUSIONS:

High to excellent Intraclass correlation coefficients were found between visits for most primary and secondary outcomes. The absolute and relative reliability, including Minimum Detectable Change values, provided in this study support the use of dual-belt instrumented treadmill walking as an acceptable medium to collect biomechanical and lower extremity EMG outcomes for future studies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Teste de Esforço / Variação Biológica Individual / Marcha Limite: Adult / Female / Humans / Male Idioma: En Revista: J Electromyogr Kinesiol Assunto da revista: FISIOLOGIA Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Teste de Esforço / Variação Biológica Individual / Marcha Limite: Adult / Female / Humans / Male Idioma: En Revista: J Electromyogr Kinesiol Assunto da revista: FISIOLOGIA Ano de publicação: 2020 Tipo de documento: Article