Your browser doesn't support javascript.
loading
Importance of attenuation correction in PET/MR image quantification: Methods and applications. / Importancia de la corrección de atenuación en la cuantificación de imagen PET/RM: métodos y aplicaciones.
Torrado-Carvajal, A.
Afiliação
  • Torrado-Carvajal A; Laboratorio de Análisis de Imagen Médica y Biometría, Universidad Rey Juan Carlos, Madrid, España; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, Estados Unidos. Electronic address: angel.torrado@urjc.es.
Article em En, Es | MEDLINE | ID: mdl-32345573
ABSTRACT
The generation of accurate attenuation correction (AC) maps is a basic step to allow for quantitative PET/MR imaging. However, generating MR-based AC maps is a challenge because there is no direct relationship between the PET attenuation coefficients (µ) and the intensity of the MR signal, contrary to what happens with the intensity of CT images. In fact, ignoring the bone causes a distorted and biased distribution of the calculated SUV values. To solve this problem, several MR-based AC methods have been proposed in the literature. In this paper we describe how these methods work, and the challenge they faced to translate into full body applications. Currently, in research environments, the accuracy of AC methods is no longer a limiting factor to solve in order to carry out quantitative in vivo molecular imaging studies. However, many of these methods present a series of limitations for their real implementation in the clinical practice due to insufficient clinical validation and the difficulty of their implementation in a real environment (as described in the examples of clinical applications). Thus, we need the PET/MR community to work on the standardization of the use and assessment of different AC methods. In this scenario, the opening and access by vendors to the implementation of new AC methods in their PET/MR scanners plays a crucial role.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Tomografia por Emissão de Pósitrons Limite: Humans Idioma: En / Es Revista: Rev Esp Med Nucl Imagen Mol (Engl Ed) Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Tomografia por Emissão de Pósitrons Limite: Humans Idioma: En / Es Revista: Rev Esp Med Nucl Imagen Mol (Engl Ed) Ano de publicação: 2020 Tipo de documento: Article