Your browser doesn't support javascript.
loading
L-glutamine as a T2 exchange contrast agent.
Joo, Chan Gyu; Yang, Seung-Hyun; Choi, Yuna; Son, Hye-Young; Kim, Dong-Hyun; Huh, Yong-Min.
Afiliação
  • Joo CG; Severance Biomedical Science Institute, College of Medicine, Yonsei University, Seoul, Korea.
  • Yang SH; Department of Radiology, College of Medicine, Yonsei University, Seoul, Korea.
  • Choi Y; Department of Radiology, College of Medicine, Yonsei University, Seoul, Korea.
  • Son HY; Severance Biomedical Science Institute, College of Medicine, Yonsei University, Seoul, Korea.
  • Kim DH; Department of Radiology, College of Medicine, Yonsei University, Seoul, Korea.
  • Huh YM; Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea.
Magn Reson Med ; 84(4): 2055-2062, 2020 10.
Article em En | MEDLINE | ID: mdl-32406063
ABSTRACT

PURPOSE:

The potential of L-glutamine as a T2 exchange contrast agent in MRI was investigated.

METHODS:

The T2 relaxation rate of L-glutamine solutions prepared in various concentrations was measured at 9.4 T. A series of T2 -weighted images in a mouse cancer model was acquired with an L-glutamine solution infusion.

RESULTS:

The T2 relaxivity caused by the exchange (R2ex ) at 37°C was 0.069 s-1 mM-1 and 0.102 s-1 mM-1 for glutamine and glutamate solutions at pH = 7.2, respectively. The R2ex of glutamine at pH = 6.1-6.7 was in the 0.097-0.1 s-1 mM-1 range. No significant dependence of T1 on the concentration of glutamine was observed. The dynamic measurement of T2 -weighted images in vivo showed that the glutamine uptake was primarily observed at the localized part of the tumor

CONCLUSION:

L-glutamine can be used as a T2 exchange contrast agent and images of glutamine uptake in vivo can be acquired.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Meios de Contraste / Glutamina Limite: Animals Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Meios de Contraste / Glutamina Limite: Animals Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article