Your browser doesn't support javascript.
loading
Internal exposure rate conversion coefficients and absorbed fractions of mouse for 137Cs, 134Cs and 90Sr contamination in body.
Endo, Satoru; Matsutani, Yuki; Kajimoto, Tsuyoshi; Tanaka, Kenichi; Suzuki, Masatoshi.
Afiliação
  • Endo S; Quantum Energy Applications, Graduate School of Advanced Science and Engineering, Hiroshima University, 1-4-1 Kagamiyama, Higashi-Hiroshima 739-8527, Japan.
  • Matsutani Y; Quantum Energy Applications, Graduate School of Advanced Science and Engineering, Hiroshima University, 1-4-1 Kagamiyama, Higashi-Hiroshima 739-8527, Japan.
  • Kajimoto T; Quantum Energy Applications, Graduate School of Advanced Science and Engineering, Hiroshima University, 1-4-1 Kagamiyama, Higashi-Hiroshima 739-8527, Japan.
  • Tanaka K; Quantum Energy Applications, Graduate School of Advanced Science and Engineering, Hiroshima University, 1-4-1 Kagamiyama, Higashi-Hiroshima 739-8527, Japan.
  • Suzuki M; International Research Institute of Disaster Science (IRIDeS), Tohoku University, Aramaki Aza-Aoba 468-1, Aoba-ku, Sendai 980-8572, Japan.
J Radiat Res ; 61(4): 535-545, 2020 Jul 06.
Article em En | MEDLINE | ID: mdl-32500146
ABSTRACT
The aim of this study was to determine parameters for estimating the internal exposure of all organs in mouse experiments from the radioactivity concentration in organs. The estimation of internal exposure rate conversion coefficients and absorbed fractions for 137Cs, 134Cs and 90Sr by the Particle and Heavy Ion Transport code System (PHITS) with a voxel-based mouse phantom is presented. The geometry of the voxel phantom is constructed from computer tomography images of a mouse 9 cm in length weighing 23.9 g. The voxel-based mouse phantom has the following organs brain, skull, heart, lungs, liver, stomach, spleen, kidneys, bladder, testis and tissue (tissue and other organs). Gamma- and beta-rays from 137Cs, 134Cs and 90Sr sources in each source organ are generated and scored for every target organ. The internal exposure rate conversion coefficients and absorbed fractions are calculated from deposition energies in each target organ from each source organ and are used to generate an internal exposure rate conversion coefficient matrix and an absorbed fraction matrix. The absorbed fractions of beta-rays in the source organs are roughly 0.5-0.8 for 137Cs and 134Cs, and the absorbed fractions of gamma-rays are <0.04 for 137Cs and <0.03 for 134Cs. The internal exposure rate conversion coefficient matrix is defined using the absorbed fractions. The calculated internal exposure rate coefficient matrix is tested under a uniform radioactivity concentration of 1 Bq/kg for 137Cs, 134Cs and 90Sr. The estimated internal exposure rates in the mouse whole body for 137Cs, 134Cs and 90Sr are 3.28 × 10-3, 2.55 × 10-3 and 1.20 × 10-2 µGy/d, respectively. These values are very similar to those for an ellipsoid frog (31.4 g) and an ellipsoid crab egg mass (12.6 g) reported in ICRP Publication 108.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Radiometria / Radioisótopos de Estrôncio / Radioisótopos de Césio Tipo de estudo: Health_economic_evaluation Limite: Animals Idioma: En Revista: J Radiat Res Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doses de Radiação / Radiometria / Radioisótopos de Estrôncio / Radioisótopos de Césio Tipo de estudo: Health_economic_evaluation Limite: Animals Idioma: En Revista: J Radiat Res Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Japão