Your browser doesn't support javascript.
loading
Variability in Streptavidin-Sepharose Matrix Quality Can Significantly Affect Proximity-Dependent Biotinylation (BioID) Data.
St-Germain, Jonathan R; Samavarchi Tehrani, Payman; Wong, Cassandra; Larsen, Brett; Gingras, Anne-Claude; Raught, Brian.
Afiliação
  • St-Germain JR; Princess Margaret Cancer Centre, University Health Network, University of Toronto, 101 College Street, Toronto, ON M5G 1L7, Canada.
  • Samavarchi Tehrani P; Lunenfeld-Tanenbaum Research Institute, Sinai Health System, and Department of Molecular Genetics, University of Toronto, 600 University Avenue, Toronto, ON M5G 1X5, Canada.
  • Wong C; Lunenfeld-Tanenbaum Research Institute, Sinai Health System, and Department of Molecular Genetics, University of Toronto, 600 University Avenue, Toronto, ON M5G 1X5, Canada.
  • Larsen B; Lunenfeld-Tanenbaum Research Institute, Sinai Health System, and Department of Molecular Genetics, University of Toronto, 600 University Avenue, Toronto, ON M5G 1X5, Canada.
  • Gingras AC; Lunenfeld-Tanenbaum Research Institute, Sinai Health System, and Department of Molecular Genetics, University of Toronto, 600 University Avenue, Toronto, ON M5G 1X5, Canada.
  • Raught B; Department of Molecular Genetics, University of Toronto, Toronto, ON M5S 1A8, Canada.
J Proteome Res ; 19(8): 3554-3561, 2020 08 07.
Article em En | MEDLINE | ID: mdl-32628020
ABSTRACT
Due to their ease of use and high binding affinity, streptavidin-based purification tools have become widely used for isolating biotinylated compounds from complex mixtures. We and others routinely use streptavidin-sepharose matrices to isolate biotinylated polypeptides generated in proximity-dependent biotinylation approaches, such as BioID or APEX. However, we noted sporadic, substantial variation in the quality of BioID experiments performed in the same laboratories over time, using seemingly identical protocols. Identifying the source of this problem, here, we highlight considerable variability in streptavidin contamination derived from different production lots of streptavidin-sepharose beads from the same manufacturer and demonstrate that high levels of streptavidin peptide contamination can have detrimental effects on BioID data. We also describe two simple, rapid approaches to assess the degree of streptavidin "shedding" from individual lots of the sepharose matrix before use to avoid the use of lower quality reagent.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos / Biotina Idioma: En Revista: J Proteome Res Assunto da revista: BIOQUIMICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos / Biotina Idioma: En Revista: J Proteome Res Assunto da revista: BIOQUIMICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Canadá