Your browser doesn't support javascript.
loading
Multiplexed Detection of Analytes on Single Test Strips with Antibody-Gated Indicator-Releasing Mesoporous Nanoparticles.
Climent, Estela; Biyikal, Mustafa; Gröninger, Delia; Weller, Michael G; Martínez-Máñez, Ramón; Rurack, Knut.
Afiliação
  • Climent E; Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, 12489, Berlin, Germany.
  • Biyikal M; Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, 12489, Berlin, Germany.
  • Gröninger D; Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, 12489, Berlin, Germany.
  • Weller MG; Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, 12489, Berlin, Germany.
  • Martínez-Máñez R; Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera, s/n, 46022, Valencia, Spain.
  • Rurack K; Unidad Mixta UPV-CIPF de Investigación en Mecanismos de Enfermedades y Nanomedicina, Universitat Politècnica de València, Centro de Investigación Príncipe Felipe, C/ Eduardo Primo Yúfera 3, 46012, Valencia, Spain.
Angew Chem Int Ed Engl ; 59(52): 23862-23869, 2020 12 21.
Article em En | MEDLINE | ID: mdl-32894638
ABSTRACT
Rapid testing methods for the use directly at a point of need are expected to unfold their true potential especially when offering adequate capabilities for the simultaneous measurement of multiple analytes of interest. Considering the unique modularity, high sensitivity, and selectivity of antibody-gated indicator delivery (gAID) systems, a multiplexed assay for three small-molecule explosives (TATP, TNT, PETN) was thus developed, allowing to detect the analytes simultaneously with a single test strip at lower ppb concentrations in the liquid phase in <5 min using a fluorescence reader or a smartphone for readout. While the TNT and PETN systems were newly developed here, all the three systems also tolerated harsher matrices than buffered aqueous model solutions. Besides a single-track strip, the outstanding modularity of the hybrid biosensor materials in combination with strip-patterning technologies allowed us to obtain a multichannel strip in a straightforward manner, offering comparable analytical performance while allowing to be tailored even more to the user's need.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Angew Chem Int Ed Engl Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Angew Chem Int Ed Engl Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Alemanha