Your browser doesn't support javascript.
loading
Large-scale evaluation of ion mobility spectrometry for the rapid detection of synthetic cannabinoid receptor agonists in infused papers in prisons.
Norman, Caitlyn; McKirdy, Brian; Walker, Gillian; Dugard, Pat; NicDaéid, Niamh; McKenzie, Craig.
Afiliação
  • Norman C; Leverhulme Research Centre for Forensic Science, School of Science and Engineering, University of Dundee, Dundee, UK.
  • McKirdy B; HMP Inverness, Scottish Prison Service, Inverness, UK.
  • Walker G; Public Protection Unit, Scottish Prison Service, Edinburgh, UK.
  • Dugard P; Leverhulme Research Centre for Forensic Science, School of Science and Engineering, University of Dundee, Dundee, UK.
  • NicDaéid N; Leverhulme Research Centre for Forensic Science, School of Science and Engineering, University of Dundee, Dundee, UK.
  • McKenzie C; Leverhulme Research Centre for Forensic Science, School of Science and Engineering, University of Dundee, Dundee, UK.
Drug Test Anal ; 13(3): 644-663, 2021 Mar.
Article em En | MEDLINE | ID: mdl-33058556
ABSTRACT
Synthetic cannabinoid receptor agonists (SCRAs), colloquially known as "spice," are commonly used in prisons and enter establishments via the mail in the form of infused papers. Many prisons use benchtop ion mobility spectroscopy (IMS) instruments to screen mail and seized materials for the presence of SCRAs and other controlled substances. The selectivity and sensitivity of Rapiscan Itemiser® 3E and Itemiser® 4DN Ion Trap Mobility Spectroscopy™ (ITMS™) systems were evaluated using 21 SCRA reference standards. Some differences in the SCRA reduced mobility (K0 ) values were observed between this study and those reported previously using IMS detection systems, particularly for cumyl and quinolinyl SCRAs (e.g., 5F-PB-22, Cumyl-4CN-BINACA, and 5F-Cumyl-PEGACLONE), although this was found to have little effect at an operational level. Operational reliability of the systems was evaluated by analyzing 392 paper and card samples with known drug content. ITMS™ system results (e.g., detect or nondetect) were in agreement with gas chromatography-mass spectrometry (GC-MS) analysis in up to 95% of samples tested. Overall, this study found the ITMS™ systems tested to be effective instruments when deployed for the rapid detection of SCRA-infused papers. Used effectively and with up-to-date substance libraries, they will help reduce the supply of SCRAs into prisons and identify emerging threats as they arise. Several emerging SCRAs (5F-MPP-PICA, 5F-EMB-PICA, and 4F-MDMB-BICA) were detected for the first time in Scottish prisons between May and August 2020 as a result of routine monitoring, and all were detected using the ITMS™ systems tested.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Drogas Ilícitas / Agonistas de Receptores de Canabinoides / Espectrometria de Mobilidade Iônica Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Drug Test Anal Assunto da revista: FARMACOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Drogas Ilícitas / Agonistas de Receptores de Canabinoides / Espectrometria de Mobilidade Iônica Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Drug Test Anal Assunto da revista: FARMACOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Reino Unido