ABSTRACT
PURPOSE:
To evaluate peripapillary retinal nerve fibre layer (RNFL) thickness measured by spectral domain optical coherence tomography (OCT) in patients with Stargardt disease (STGD).METHODS:
A cross-sectional, monocentric, observational case-control study. Twenty patients (39 eyes) with ABCA4 mutations graded according to the Fishman STGD classification were included. RNFL measurement was performed using Heidelberg Spectralis SD-OCT. RNFL thickness in STGD patients was compared to age-matched data of healthy individuals provided by the device's manufacturer. A manual readjustment of the optic disc-fovea angle was performed when needed.RESULTS:
The mean age at first diagnosis of STGD was 22.9 years (range 9 to 50) and 39.1 years (range 18 to 74) at the time of examination. Thirty-nine percent of eyes (15 eyes) needed manual adjustment of the optic disc-fovea angle due to malfixation of the patients during OCT. The temporal quadrant corresponding to the macula showed a RNFL 16% thinner than controls (mean - 12 µm, 95%CI - 9 to -15 µm). However, global RNFL thickness did not differ from controls due to increased RNFL thickness of 12% in the nasal sectors. Duration and stage of STGD were not correlated to thinner RNFL.CONCLUSION:
STGD seems to be associated with thinner peripapillary RNFL in the sector of axons projecting to the degenerated macular area. It is yet unclear as to whether this results from anterograde transneuronal degeneration of direct injury to retinal ganglion cells.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Disco Óptico
/
Tomografia de Coerência Óptica
Tipo de estudo:
Guideline
/
Observational_studies
/
Prevalence_studies
/
Risk_factors_studies
Limite:
Adolescent
/
Adult
/
Child
/
Humans
/
Middle aged
Idioma:
En
Revista:
Graefes Arch Clin Exp Ophthalmol
Ano de publicação:
2021
Tipo de documento:
Article
País de afiliação:
Alemanha