Your browser doesn't support javascript.
loading
Selective electrochemical detection of antidepressant drug imipramine in blood serum and urine samples using an antimony telluride-graphite nanofiber electrode.
Yamuna, Annamalai; Chen, Tse-Wei; Chen, Shen-Ming; Al-Mohaimeed, Amal M; Al-Onazi, Wedad A; Elshikh, Mohamed Soliman.
Afiliação
  • Yamuna A; Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei, 106, Taiwan.
  • Chen TW; Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei, 106, Taiwan.
  • Chen SM; Research and Development Center for Smart Textile Technology, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei, 106, Taiwan.
  • Al-Mohaimeed AM; Department of Materials, Imperial College London, London, SW72AZ, UK.
  • Al-Onazi WA; Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No. 1, Section 3, Chung-Hsiao East Road, Taipei, 106, Taiwan. smchen78@ms15.hinet.net.
  • Elshikh MS; Department of Chemistry, College of Science, King Saud University, P.O. Box 22452, Riyadh, 11495, Saudi Arabia.
Mikrochim Acta ; 188(2): 60, 2021 01 28.
Article em En | MEDLINE | ID: mdl-33511456
ABSTRACT
A high-performance imipramine (IMPR) sensor has been developed  based on metal chalcogenide-carbon composite materials. The antimony telluride-graphite nanofiber (Sb2Te3-GNF, hereafter SBT-GNF) composite was synthesized by the hydrothermal method and confirmed by X-ray powder diffraction (XRD) pattern. The morphology, crystalline lattice, and chemical states were characterized by HRTEM, SAED, and XPS analysis. The characterizations confirmed the formation of an effective composite, SBT-GNF. The SBT-GNF was fabricated as a disposable sensor electrode with a screen-printed carbon electrode (SPCE) and examined for the detection of IMPR by differential pulse voltammetry (DPV). The electroanalytical results of SBT-GNF are compared with the SBT and GNF, and the rational design of effective composite is discussed. SBT-GNF/SPCE showed a good linear range (0.01­51.8 µM), sensitivity (1.35 ± 0.1 µA µM-1 cm-2), and low LOD (4 ± 2 nM). Moreover, the SBT-GNF/SPCE revealed high selectivity and high tolerance limit against potential interfering compounds in blood serum and urine samples. Therefore, this electrochemical sensor can be applicable for the detection of tricyclic antidepressant drug IMPR in clinical and pharmaceutical analysis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nanofibras / Imipramina / Antidepressivos Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Mikrochim Acta Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nanofibras / Imipramina / Antidepressivos Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Mikrochim Acta Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Taiwan