Your browser doesn't support javascript.
loading
A Pt-Ir nanocube amplified lateral flow immunoassay for dehydroepiandrosterone.
Yang, Huiyi; He, Qiyi; Pan, Junkang; Shen, Ding; Xiao, Huanxin; Cui, Xiping; Zhao, Suqing.
Afiliação
  • Yang H; Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China. cuixiping1989@163.com sqzhao@gdut.edu.cn.
  • He Q; Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China. cuixiping1989@163.com sqzhao@gdut.edu.cn.
  • Pan J; Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China. cuixiping1989@163.com sqzhao@gdut.edu.cn.
  • Shen D; Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China. cuixiping1989@163.com sqzhao@gdut.edu.cn.
  • Xiao H; Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China. cuixiping1989@163.com sqzhao@gdut.edu.cn.
  • Cui X; Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China. cuixiping1989@163.com sqzhao@gdut.edu.cn.
  • Zhao S; Department of Pharmaceutical Engineering, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, People's Republic of China. cuixiping1989@163.com sqzhao@gdut.edu.cn.
Analyst ; 146(8): 2726-2733, 2021 Apr 26.
Article em En | MEDLINE | ID: mdl-33709090
ABSTRACT
The traditional gold-nanoparticle-based lateral flow immunoassay (LFIA) cannot satisfy the requirements for the sensitive detection of dehydroepiandrosterone (DHEA) in human urine. To enhance the sensitivity of the LFIA, platinum-iridium nanocubes (Pt-Ir NCs) with high catalytic efficiency and stability were synthesized and labelled with polyclonal antibody (pAb) to form a pAb-Pt-Ir probe. For the detection of DHEA, a novel LFIA with Pt-Ir NCs as an optical label and an enhanced LFIA in which the peroxidase-like activity of the Pt-Ir NCs was triggered by the introduction of the chromogenic substrate 3-amino-9-ethyl-carbazole (AEC) were developed and compared with a LFIA with platinum nanocubes (PtNCs) as an optical label. The visual limit of detection was 0.5 ng mL-1 for Pt-Ir-LFIA and 0.05 ng mL-1 for AEC-enhanced Pt-Ir-LFIA, in comparison to 100 ng mL-1 for PtNCs-LFIA and 50 ng mL-1 for AEC-enhanced PtNCs-LFIA. The average recoveries from spiked urine samples ranged from 90.8% to 110.4%, with a coefficient of variation below 12.6%, suggesting the accuracy and reliability of our developed immunoassay. Achieving excellent sensitivity, specificity, and reproducibility, Pt-Ir-LFIA provided a promising platform for monitoring DHEA.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imunoensaio / Desidroepiandrosterona / Nanopartículas Metálicas Limite: Humans Idioma: En Revista: Analyst Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imunoensaio / Desidroepiandrosterona / Nanopartículas Metálicas Limite: Humans Idioma: En Revista: Analyst Ano de publicação: 2021 Tipo de documento: Article