Your browser doesn't support javascript.
loading
Biocompatibility and Biological Performance Evaluation of Additive-Manufactured Bioabsorbable Iron-Based Porous Suture Anchor in a Rabbit Model.
Tai, Chien-Cheng; Lo, Hon-Lok; Liaw, Chen-Kun; Huang, Yu-Min; Huang, Yen-Hua; Yang, Kuo-Yi; Huang, Chih-Chieh; Huang, Shin-I; Shen, Hsin-Hsin; Lin, Tzu-Hung; Lu, Chun-Kuan; Liu, Wen-Chih; Sun, Jui-Sheng; Tsai, Pei-I; Chen, Chih-Yu.
Afiliação
  • Tai CC; Internal Ph.D. Program for Cell Therapy and Regeneration Medicine, College of Medicine, Taipei Medical University, Taipei 11031, Taiwan.
  • Lo HL; Department of Orthopedic Surgery, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung 80756, Taiwan.
  • Liaw CK; Department of Orthopedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei 11031, Taiwan.
  • Huang YM; Department of Orthopedics, Shuang Ho Hospital, Taipei Medical University, No. 291, Zhongzheng Rd., Zhong He Dist., New Taipei City 23561, Taiwan.
  • Huang YH; Research Center of Biomedical Device, Graduate Institute of Biomedical Optomechatronics, College of Biomedical Engineering, Taipei Medical University, Taipei 11301, Taiwan.
  • Yang KY; Department of Orthopedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei 11031, Taiwan.
  • Huang CC; Department of Orthopedics, Shuang Ho Hospital, Taipei Medical University, No. 291, Zhongzheng Rd., Zhong He Dist., New Taipei City 23561, Taiwan.
  • Huang SI; Internal Ph.D. Program for Cell Therapy and Regeneration Medicine, College of Medicine, Taipei Medical University, Taipei 11031, Taiwan.
  • Shen HH; Department of Biochemistry and Molecular Cell Biology, School of Medicine, College of Medicine, Taipei Medical University, Taipei 11031, Taiwan.
  • Lin TH; TMU Research Center of Cell Therapy and Regeneration Medicine, Taipei Medical University, Taipei 11031, Taiwan.
  • Lu CK; Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Chutung, Hsinchu 310401, Taiwan.
  • Liu WC; Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Chutung, Hsinchu 310401, Taiwan.
  • Sun JS; Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Chutung, Hsinchu 310401, Taiwan.
  • Tsai PI; Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Chutung, Hsinchu 310401, Taiwan.
  • Chen CY; Material and Chemical Research Laboratories, Industrial Technology Research Institute, Hsinchu 31040, Taiwan.
Int J Mol Sci ; 22(14)2021 Jul 08.
Article em En | MEDLINE | ID: mdl-34298988
ABSTRACT
This study evaluated the biocompatibility and biological performance of novel additive-manufactured bioabsorbable iron-based porous suture anchors (iron_SAs). Two types of bioabsorbable iron_SAs, with double- and triple-helical structures (iron_SA_2_helix and iron_SA_3_helix, respectively), were compared with the synthetic polymer-based bioabsorbable suture anchor (polymer_SAs). An in vitro mechanical test, MTT assay, and scanning electron microscope (SEM) analysis were performed. An in vivo animal study was also performed. The three types of suture anchors were randomly implanted in the outer cortex of the lateral femoral condyle. The ultimate in vitro pullout strength of the iron_SA_3_helix group was significantly higher than the iron_SA_2_helix and polymer_SA groups. The MTT assay findings demonstrated no significant cytotoxicity, and the SEM analysis showed cells attachment on implant surface. The ultimate failure load of the iron_SA_3_helix group was significantly higher than that of the polymer_SA group. The micro-CT analysis indicated the iron_SA_3_helix group showed a higher bone volume fraction (BV/TV) after surgery. Moreover, both iron SAs underwent degradation with time. Iron_SAs with triple-helical threads and a porous structure demonstrated better mechanical strength and high biocompatibility after short-term implantation. The combined advantages of the mechanical superiority of the iron metal and the possibility of absorption after implantation make the iron_SA a suitable candidate for further development.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Materiais Biocompatíveis / Implantes Absorvíveis / Âncoras de Sutura Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Int J Mol Sci Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Materiais Biocompatíveis / Implantes Absorvíveis / Âncoras de Sutura Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Revista: Int J Mol Sci Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Taiwan