Hydrogen Detection Limits and Instrument Sensitivity of High-Resolution Broadband Neutron Spectrometers.
Scatigno, Claudia; Zanetti, Matteo; Rudic, Svemir; Senesi, Roberto; Andreani, Carla; Gorini, Giuseppe; Fernandez-Alonso, Felix.
Afiliação
  • Scatigno C; ISIS Facility, STFC, Rutherford Appleton Laboratory, Chilton, Didcot OX11 0QX, U.K.
  • Zanetti M; Centro Fermi─Museo Storico della Fisica e Centro Studi e Ricerche 'Enrico Fermi', Piazza del Viminale 1, 00184 Roma, Italy.
  • Rudic S; Università degli Studi di Roma "Tor Vergata", Dipartimento di Scienze e Tecnologie Chimiche, Piazzale Aldo Moro 7, 00185 Roma, Italy.
  • Senesi R; ISIS Facility, STFC, Rutherford Appleton Laboratory, Chilton, Didcot OX11 0QX, U.K.
  • Andreani C; Consiglio Nazionale delle Ricerche, Dipartimento di Scienze Fisiche e Tecnologie della Materia, 00185 Roma, Italy.
  • Gorini G; ISIS Facility, STFC, Rutherford Appleton Laboratory, Chilton, Didcot OX11 0QX, U.K.
  • Fernandez-Alonso F; Università degli Studi di Roma "Tor Vergata", Dipartimento di Fisica and Centro NAST, Via della Ricerca Scientifica 1, 00133 Roma, Italy.
Anal Chem ; 94(12): 5023-5028, 2022 03 29.
Article em En | MEDLINE | ID: mdl-35298136
ABSTRACT
The limits of detection (LOD) and quantitation (LOQ) in the mass domain, for broadband vibrational spectroscopy with neutrons on the TOSCA spectrometer at the ISIS Pulsed Neutron and Muon Source (UK), have been studied. The well-known 3σ and 10σ approaches are used through a specifically developed analytical procedure that is based on the calculation of the integrated spectral intensities in selected energy-transfer ranges, as a function of mass of standard reference materials and calibrants, such as ZrH2, 2,5-diiodothiophene, and low-density polyethylene. The analysis shows that the blank, that is, the instrument setup without the analyte, plays a critical role in the measurement performance, especially for small specimen quantities. The results point that TOSCA enables detection of 128 µmol (LODH) and quantitation of 428 µmol (LOQH) of elemental hydrogen analytes in ZrH2. The determined values for this and other standards allow for the assessment of the calibration curve design and instrument sensitivity and define a method to be used for inelastic neutron scattering spectrometers such as TOSCA, or VESPA, the new beamline under construction at the European Spallation Source in Lund (Sweden).
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hidrogênio / Nêutrons Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chem Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Reino Unido