Comparison of the performance of conventional and spectral-based tagged stool cleansing algorithms at CT colonography.
Eur Radiol
; 32(11): 7936-7945, 2022 Nov.
Article
em En
| MEDLINE
| ID: mdl-35486170
ABSTRACT
OBJECTIVES:
To compare the performance of conventional versus spectral-based electronic stool cleansing for iodine-tagged CT colonography (CTC) using a dual-layer spectral detector scanner.METHODS:
We retrospectively evaluated iodine contrast stool-tagged CTC scans of 30 consecutive patients (mean age 69 ± 8 years) undergoing colorectal cancer screening obtained on a dual-layer spectral detector CT scanner. One reader identified locations of electronic cleansing artifacts (n = 229) on conventional and spectral cleansed images. Three additional independent readers evaluated these locations using a conventional cleansing algorithm (Intellispace Portal) and two experimental spectral cleansing algorithms (i.e., fully transparent and translucent tagged stool). For each cleansed image set, readers recorded the severity of over- and under-cleansing artifacts on a 5-point Likert scale (0 = none to 4 = severe) and readability compared to uncleansed images. Wilcoxon's signed-rank tests were used to assess artifact severity, type, and readability (worse, unchanged, or better).RESULTS:
Compared with conventional cleansing (66% score ≥ 2), the severity of overall cleansing artifacts was lower in transparent (60% score ≥ 2, p = 0.011) and translucent (50% score ≥ 2, p < 0.001) spectral cleansing. Under-cleansing artifact severity was lower in transparent (49% score ≥ 2, p < 0.001) and translucent (39% score ≥ 2, p < 0.001) spectral cleansing compared with conventional cleansing (60% score ≥ 2). Over-cleansing artifact severity was worse in transparent (17% score ≥ 2, p < 0.001) and translucent (14% score ≥ 2, p = 0.023) spectral cleansing compared with conventional cleansing (9% score ≥ 2). Overall readability was significantly improved in transparent (p < 0.001) and translucent (p < 0.001) spectral cleansing compared with conventional cleansing.CONCLUSIONS:
Spectral cleansing provided more robust electronic stool cleansing of iodine-tagged stool at CTC than conventional cleansing. KEY POINTS ⢠Spectral-based electronic cleansing of tagged stool at CT colonography provides higher quality images with less perception of artifacts than does conventional cleansing. ⢠Spectral-based electronic cleansing could potentially advance minimally cathartic approach for CT colonography. Further clinical trials are warranted.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Colonografia Tomográfica Computadorizada
/
Iodo
Tipo de estudo:
Observational_studies
/
Prognostic_studies
Limite:
Aged
/
Humans
/
Middle aged
Idioma:
En
Revista:
Eur Radiol
Assunto da revista:
RADIOLOGIA
Ano de publicação:
2022
Tipo de documento:
Article
País de afiliação:
Estados Unidos