Your browser doesn't support javascript.
loading
The predictive value of the sFlt-1/PlGF ratio in suspected preeclampsia in a New Zealand population: A prospective cohort study.
Hughes, Ruth C E; Phillips, Ian; Florkowski, Chris M; Gullam, Joanna.
Afiliação
  • Hughes RCE; Christchurch Women's Hospital, Canterbury District Health Board, Christchurch, New Zealand.
  • Phillips I; Department of Obstetrics and Gynaecology, University of Otago, Christchurch, New Zealand.
  • Florkowski CM; Head of Endocrine and Steroid Laboratory, Canterbury Health Laboratories, Christchurch, New Zealand.
  • Gullam J; Consultant in Chemical Pathology: Canterbury Health Laboratories, Christchurch, New Zealand.
Aust N Z J Obstet Gynaecol ; 63(1): 34-41, 2023 02.
Article em En | MEDLINE | ID: mdl-35670085
ABSTRACT

BACKGROUND:

Internationally, placental growth factor (PlGF)-based tests are used as prognostic markers in suspected preeclampsia. However, Ministry of Health guidelines do not currently endorse PlGF-based tests in New Zealand (NZ).

AIMS:

To investigate the predictive value of soluble fms-like tyrosine kinase 1 (sFlt-1)/PlGF ratio in suspected preeclampsia in a NZ population. MATERIALS AND

METHODS:

A prospective cohort study of singleton pregnancies at 20+0 -36+6 weeks gestation with suspected preeclampsia as defined by Society of Obstetric Medicine Australia and NZ (SOMANZ) criteria. PRIMARY

OBJECTIVE:

to evaluate a sFlt-1/PlGF ratio >38 at ≤35+0 weeks gestation to predict birth ≤14 days. SECONDARY

OBJECTIVES:

to assess a sFlt-1/PlGF ratio cut-off of 38 at ≤37+0 weeks gestation, to rule out preeclampsia ≤1 week, rule in preeclampsia ≤4 weeks, and to predict perinatal outcome. Clinicians were blinded to sFlt-1/PlGF ratio results.

RESULTS:

Included were 222 participants, 19.4% Maori and 10.4% Pasifika. A sFlt-1/PlGF >38 predicted birth ≤14 days, positive predictive value (PPV) 51.4% (95% CI, 39.6-63.0) and negative predictive value (NPV) 95.9% (95% CI, 91.4-98.1), median (interquartile range) days to birth 14 (2-27) vs 49 (33-70), P < 0.000. A sFlt-1/PlGF cut-off of 38 ruled out preeclampsia ≤1 week (NPV 96.2% (95% CI, 92.3-98.2)) and ruled in preeclampsia ≤4 weeks (PPV 75.0% (95% CI, 65.0-82.9)). A sFlt-1/PlGF >38 was associated with greater perinatal morbidity.

CONCLUSIONS:

The predictive value of the sFlt-1/PlGF ratio in NZ is comparable to that reported in international trials. Used in clinical practice the sFlt-1/PlGF ratio may aid risk stratification in suspected preeclampsia, directing limited resources to those pregnancies at highest risk.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pré-Eclâmpsia Tipo de estudo: Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Pregnancy País/Região como assunto: Oceania Idioma: En Revista: Aust N Z J Obstet Gynaecol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Nova Zelândia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pré-Eclâmpsia Tipo de estudo: Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Pregnancy País/Região como assunto: Oceania Idioma: En Revista: Aust N Z J Obstet Gynaecol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Nova Zelândia