Your browser doesn't support javascript.
loading
Measurements of Anti-SARS-CoV-2 Antibody Levels after Vaccination Using a SH-SAW Biosensor.
Cheng, Chia-Hsuan; Peng, Yu-Chi; Lin, Shu-Min; Yatsuda, Hiromi; Liu, Szu-Heng; Liu, Shih-Jen; Kuo, Chen-Yen; Wang, Robert Y L.
Afiliação
  • Cheng CH; Tst Biomedical Electronics Co., Ltd., Taoyuan 324403, Taiwan.
  • Peng YC; Tst Biomedical Electronics Co., Ltd., Taoyuan 324403, Taiwan.
  • Lin SM; Biotechnology Industry Master and Ph.D. Program, Chang Gung University, Taoyuan 33302, Taiwan.
  • Yatsuda H; Department of Thoracic Medicine, Chang Gung Memorial Hospital, Linkou 33305, Taiwan.
  • Liu SH; Tst Biomedical Electronics Co., Ltd., Taoyuan 324403, Taiwan.
  • Liu SJ; Tst Biomedical Electronics Co., Ltd., Taoyuan 324403, Taiwan.
  • Kuo CY; National Institute of Infectious Diseases and Vaccinology, Taoyuan 33302, Taiwan.
  • Wang RYL; Division of Pediatric Infectious Diseases, Department of Pediatrics, Chang Gung Memorial and Children's Hospital, Linkou 33305, Taiwan.
Biosensors (Basel) ; 12(8)2022 Aug 04.
Article em En | MEDLINE | ID: mdl-36004995
ABSTRACT
To prevent the COVID-19 pandemic that threatens human health, vaccination has become a useful and necessary tool in the response to the pandemic. The vaccine not only induces antibodies in the body, but may also cause adverse effects such as fatigue, muscle pain, blood clots, and myocarditis, especially in patients with chronic disease. To reduce unnecessary vaccinations, it is becoming increasingly important to monitor the amount of anti-SARS-CoV-2 S protein antibodies prior to vaccination. A novel SH-SAW biosensor, coated with SARS-CoV-2 spike protein, can help quantify the amount of anti-SARS-CoV-2 S protein antibodies with 5 µL of finger blood within 40 s. The LoD of the spike-protein-coated SAW biosensor was determined to be 41.91 BAU/mL, and the cut-off point was determined to be 50 BAU/mL (Youden's J statistic = 0.94733). By using the SH-SAW biosensor, we found that the total anti-SARS-CoV-2 S protein antibody concentrations spiked 10−14 days after the first vaccination (p = 0.0002) and 7−9 days after the second vaccination (p = 0.0116). Furthermore, mRNA vaccines, such as Moderna or BNT, could achieve higher concentrations of total anti-SARS-CoV-2 S protein antibodies compared with adenovirus vaccine, AZ (p < 0.0001). SH-SAW sensors in vitro diagnostic systems are a simple and powerful technology to investigate the local prevalence of COVID-19.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vacinas Virais / Técnicas Biossensoriais / COVID-19 Tipo de estudo: Diagnostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Biosensors (Basel) Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vacinas Virais / Técnicas Biossensoriais / COVID-19 Tipo de estudo: Diagnostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Biosensors (Basel) Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Taiwan