A Novel System for the Measurement of an Evaporation Duct Using the Magnetic Coupling Principle for Power Feeding and Data Transmission.
Wang, Qiang; Li, Xingfei; Li, Hongyu; Yang, Shaobo; Yang, Shizhong; Ma, Linlin; Zhao, Jingbo.
Afiliação
  • Wang Q; College of Information and Control Engineering, Qingdao University of Technology, Qingdao 266525, China.
  • Li X; State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China.
  • Li H; State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China.
  • Yang S; College of Ocean Science and Engineer, Shandong University of Science and Technology, Qingdao 266590, China.
  • Yang S; College of Ocean Science and Engineer, Shandong University of Science and Technology, Qingdao 266590, China.
  • Ma L; College of Information and Control Engineering, Qingdao University of Technology, Qingdao 266525, China.
  • Zhao J; College of Information and Control Engineering, Qingdao University of Technology, Qingdao 266525, China.
Sensors (Basel) ; 22(19)2022 Sep 28.
Article em En | MEDLINE | ID: mdl-36236482
ABSTRACT
Since the evaporation duct height (EDH) only covers the antenna height of most shipborne microwave radars, mastering the EDH in advance has great significance in achieving long-range target detection. In this paper, a set of hydrological and meteorological sensors based on the gradient meteorological instrument (GMI) were built to monitor the evaporation duct of the South China Sea (SCS). However, the monitoring needed to be interrupted during the battery replacement of the sensor, which could result in the loss of some important data collection. On the basis of the inductively coupled power transfer (ICPT) technology, the resonance principle was used to compensate the inductive reactance on the closed steel ring (CSR), and the energy stored in the super capacitor was introduced for data collection and return. A novel measuring system for the detection of an evaporation duct was proposed. To avoid iterative calculation by setting the initial value of the current evaporation duct models in large-scale and multi time evaporation duct prediction and diagnosis, on the basis of the non-iterative air-sea flux (NAF) model, the EDH was obtained by introducing the K theoretical flux observation method into the atmospheric refractive index equation. Finally, preliminary experimental results are presented for the detection of evaporation duct to demonstrate the feasibility and effectiveness of the proposed system. The communication accuracy rate of the proposed system was 99.7%. The system transmission power reached 22.8 W. The research results of the NAF model adaptability showed that the mean value of the EDH was 8.7 m, which was lower than the mean EDH of the SCS. The EDH calculated by the NAF model in the unstable air-sea stratification state was slightly lower than that calculated by the NPS model. The diagnosis of the EDH by the NAF model was similar to that of the NPS model, but the calculation stability of the NAF model was better.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China