EXAMINATION OF LENS EXPOSURE DOSES OF CARDIOLOGISTS, NEUROSURGEONS AND RADIOLOGISTS IN INTERVENTIONAL RADIOLOGY.
Osawa, Mitsuharu; Tawada, Yuka; Kaneda, Naoki; Fujita, Naotoshi; Koyama, Shuji.
Afiliação
  • Osawa M; Department of Radiology, Aichi Medical University Hospital, Nagakute, 480-1195, Japan.
  • Tawada Y; Department of Radiology, Aichi Medical University Hospital, Nagakute, 480-1195, Japan.
  • Kaneda N; Department of Radiology, Aichi Medical University Hospital, Nagakute, 480-1195, Japan.
  • Fujita N; Department of Radiological Technology, Nagoya University Hospital, Nagoya, 466-8560, Japan.
  • Koyama S; Brain and Mind Research Center, Nagoya University, Department of Brain and Mind Sciences, Nagoya University Graduate School of Medicine, Nagoya, 461-8673, Japan.
Radiat Prot Dosimetry ; 198(20): 1585-1597, 2022 Dec 07.
Article em En | MEDLINE | ID: mdl-36321327
ABSTRACT
The International Commission on Radiological Protection (ICRP) 118th recommendation significantly reduced the threshold dose for cataract development from 8 to 0.5 Gy. Equivalent dose limits for the crystalline lenses of radiation workers are being reviewed for individual countries. Interventional radiology (IR) procedures are less invasive than surgery and have become widespread; however, there are concerns about exposure not only to patients but also to staff, including operators. Therefore, in this study, we used a human phantom to measure the near-lens dose of the operators (cardiologists, neurosurgeons and radiologists) and estimated the operator's lens dose for every major procedure in each clinical department; this was found to vary. Owing to the different imaging and fluoroscopy conditions of each department, and the varying ratio of fluoroscopy to radiography, it is necessary to measure the lens dose for each condition, as in this study. In addition, this study explains the differences between the protective effect of various safety equipment and the appropriate use of protective plates; it can contribute to the reduction of lens doses for operators.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Japão