Atrial fibrillation detection using insertable cardiac monitor after stroke: A real-world cohort study.
Noubiap, Jean J; Thomas, Gijo; Middeldorp, Melissa E; Fitzgerald, John L; Harper, Curtis; Sanders, Prashanthan.
Afiliação
  • Noubiap JJ; Centre for Heart Rhythm Disorders, University of Adelaide, Adelaide, Australia.
  • Thomas G; Department of Cardiology, Royal Adelaide Hospital, Adelaide, Australia.
  • Middeldorp ME; Centre for Heart Rhythm Disorders, University of Adelaide, Adelaide, Australia.
  • Fitzgerald JL; Centre for Heart Rhythm Disorders, University of Adelaide, Adelaide, Australia.
  • Harper C; Department of Cardiology, Royal Adelaide Hospital, Adelaide, Australia.
  • Sanders P; Centre for Heart Rhythm Disorders, University of Adelaide, Adelaide, Australia.
J Cardiovasc Electrophysiol ; 34(1): 142-146, 2023 01.
Article em En | MEDLINE | ID: mdl-36349715
ABSTRACT

OBJECTIVE:

This study aimed to report the real-world atrial fibrillation (AF) diagnostic yield of the implantable cardiac monitor (ICM) in patients with stroke or transient ischemic attack (TIA), and compare it to patients with an ICM for unexplained syncope.

METHODS:

We used patient data from device clinics across the United States of America with ICM remote monitoring via PaceMate™, implanted for stroke or TIA, and unexplained syncope. Patients with known AF or atrial flutter were excluded. The outcome was AF lasting ≥2 min, adjudicated by International Board of Heart Rhythm Examiners certified cardiac device specialists.

RESULTS:

We included a total of 2469 patients, 51.1% with stroke or TIA (mean age 69.7 [SD 12.2] years, 41.1% female) and 48.9% with syncope (mean age 67.0 [SD 17.1] years, 59.4% female). The cumulative AF detection rate in patients with stroke or TIA was 5.5%, 8.9%, and 14.0% at 12, 24, and 36 months, respectively. The median episode duration was 73 (interquartile range 10-456) min, ranging from 2 min to 40.9 days, with 52.3%, 28.6%, and 4.4% of episodes lasting at least 1, 6, and 24 h, respectively. AF detection was increased by age (adjusted hazard ratio [for every 1-year increase] 1.024, 95% confidence interval 1.008-1.040; p = .003), but was not influenced by sex (p = .089). For comparison, the cumulative detection rate at 12, 24, and 36 months were, respectively, 2.4%, 5.2%, and 7.4% in patients with syncope.

CONCLUSION:

Patients with stroke or TIA have a higher rate of AF detection. However, this real-world study shows significantly lower AF detection rates than what has been previously reported.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Ataque Isquêmico Transitório / Acidente Vascular Cerebral Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: J Cardiovasc Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Ataque Isquêmico Transitório / Acidente Vascular Cerebral Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: J Cardiovasc Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Austrália