Your browser doesn't support javascript.
loading
Electrochemical impedimetric immunosensor based on stabilized lipid bilayer-tethered WS2@MWCNT for the sensitive detection of carcinoembryonic antigen.
Keerthana, S; Divya, K P; Rajapriya, A; Viswanathan, C; Ponpandian, N.
Afiliação
  • Keerthana S; Department of Nanoscience and Technology, Bharathiar University, Coimbatore, 641 046, India.
  • Divya KP; Department of Nanoscience and Technology, Bharathiar University, Coimbatore, 641 046, India.
  • Rajapriya A; Bharathiar Cancer Theranostics Research Centre, Bharathiar University, Coimbatore, 641 046, India.
  • Viswanathan C; Department of Nanoscience and Technology, Bharathiar University, Coimbatore, 641 046, India.
  • Ponpandian N; Department of Nanoscience and Technology, Bharathiar University, Coimbatore, 641 046, India.
Mikrochim Acta ; 189(12): 450, 2022 11 18.
Article em En | MEDLINE | ID: mdl-36401138
ABSTRACT
An innovative and ultrasensitive electrochemical impedimetric immunosensor was developed for the quantitative detection towards carcinoembryonic antigen (CEA). CEA is a widely utilized tumour biomarker that is generated in a wide variety of cancers and it is a frequently used biomarker for clinical research and early detection of cancer. Novelty of the present work is the utilization of biomimetic membrane comprising gold nanoparticle-stabilized lipid bilayer (SLB) containing DOPE (1,2-dioleoyl-sn-glycero-3-phosphoethanolamine) and DOTAP (N-[1-(2,3-Dioleoyloxy)propyl]-N,N,N-trimethyl ammonium Propane) for easy protein insertion, bio-affinity, and bio-functionalization towards the detection of CEA. The SLB is tethered on stable tungsten disulfide decorated MWCNT (WS2@MWCNT) surface for the sensitive and selective detection of CEA. The WS2@MWCNT surface has been chosen to tether SLB due to its numerous unique characteristics such as greater surface area, high conductivity, and excellent electronic conductivity, which in turn leads to the improvement of the superior electrochemical sensing ability towards CEA. The lone SLB when used for protein insertion lacks space and impedes the functional incorporation of transmembrane proteins with hydrophilic domains on both sides and biosensing applications. The SLB-tethered WS2@MWCNT surface (SLB-WS2@MWCNT) was examined by studying the electrochemical changes in the existence of redox probe K3/K4 [Fe(CN)6] through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The combined excellent properties of WS2@MWCNT and SLB have shown to amplify the sensitive detection of CEA with a LOD value of 0.2 pg mL-1. The developed sensor provides higher stability, sensitivity, and excellent reproducibility towards the detection of CEA with relative standard deviation (RSD) of < 5%. The encouraging results demonstrate that the CEA impedimetric immunosensor has potential in practical analysis and lays a solid platform for additional biomarker detection in early clinical diagnosis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Revista: Mikrochim Acta Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Revista: Mikrochim Acta Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Índia