Hybrid approach for harmony transcatheter pulmonary valve replacement.
Catheter Cardiovasc Interv
; 101(1): 135-139, 2023 01.
Article
em En
| MEDLINE
| ID: mdl-36434791
ABSTRACT
The Harmony™ Transcatheter Pulmonary Valve (Medtronic) was recently approved by the Food and Drug Administration for transcatheter pulmonary valve replacement in native right ventricular outflow tracts. Despite this milestone, some patients have main pulmonary arteries that are severely dilated and continue to require surgical pulmonary valve replacement. The hybrid approach combines surgical creation of a landing zone, transcatheter valve deployment, and suture stabilization of the implanted valve. In this case series, we report the first use of a hybrid approach for Harmony™ transcatheter pulmonary valve replacement. Two cases are reported with varying approaches for surgical creation of a landing zone followed by successful placement of a Harmony™ valve.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Valva Pulmonar
/
Insuficiência da Valva Pulmonar
/
Próteses Valvulares Cardíacas
/
Implante de Prótese de Valva Cardíaca
Limite:
Humans
Idioma:
En
Revista:
Catheter Cardiovasc Interv
Assunto da revista:
CARDIOLOGIA
Ano de publicação:
2023
Tipo de documento:
Article
País de afiliação:
Estados Unidos