Your browser doesn't support javascript.
loading
Comparison of six microscopic methods and two operators for estimation of white and red blood cells in canine urine sediment.
Giraldi, Marco; Tagliasacchi, Filippo; Paltrinieri, Saverio; Vitiello, Tiziana; Rossetti, Paola; Scarpa, Paola.
Afiliação
  • Giraldi M; Department of Veterinary Medicine and Animal Sciences, University of Milan, Lodi, Italy.
  • Tagliasacchi F; Laboratorio di Analisi Veterinarie MYLAV, Passirana di Rho, Milan, Italy.
  • Paltrinieri S; Department of Veterinary Medicine and Animal Sciences, University of Milan, Lodi, Italy.
  • Vitiello T; Department of Veterinary Medicine and Animal Sciences, University of Milan, Lodi, Italy.
  • Rossetti P; Department of Veterinary Medicine and Animal Sciences, University of Milan, Lodi, Italy.
  • Scarpa P; Department of Veterinary Medicine and Animal Sciences, University of Milan, Lodi, Italy.
Vet Clin Pathol ; 52(1): 71-78, 2023 Mar.
Article em En | MEDLINE | ID: mdl-36464323
ABSTRACT

BACKGROUND:

Little information is currently available about the analytical variability of urinalysis.

OBJECTIVE:

We aimed to compare results obtained by two operators using six microscopic methods in the quantification of urinary leukocytes (WBC) and erythrocytes (RBC).

METHODS:

Forty urine samples (10 mL) were centrifuged (450g, 5 minutes) and resuspended in 0.5 mL of supernatant. Two operators with different expertise in urinalysis interpreted sediment results using the six methods, obtained by combining the use of microscope slides (Slide) or counting chambers (Chamber) with three different techniques bright-field (BF) microscopy, phase-contrast (PC) microscopy, and stained sediment (SS) evaluations. The mean WBC and RBC counts from 10 fields (Slide) or squares (Chamber) observed at 400× were used to calculate the difference and agreement between operators and methods. We also estimated the concordance between methods in classifying microhematuric or pyuric samples.

RESULTS:

Operator 2 counted significantly lower WBC counts using Slide+BF (P = 0.009) and Slide+PC (P = 0.001) than Operator 1, whereas no inter-operator differences were recorded for RBC counts. The concordance between the operators ranged from "good" to "very good." No differences or biases were found for WBC counts among the methods, and concordances were "good" to "very good"; proportional biases were found for RBC counts between Slide+BF vs Slide+SS and Slide+PC vs Slide+SS. Concordance measurements for RBC counts ranged from "good" to "very good."

CONCLUSIONS:

All methods yielded good reproducibility among operators, although stained SS evaluations allowed better identification of WBC by the inexperienced operator. However, we suspected that the SS preparations affected RBC counts. All other methods yielded reproducible WBC and RBC counts.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Urinálise / Eritrócitos Limite: Animals Idioma: En Revista: Vet Clin Pathol Assunto da revista: MEDICINA VETERINARIA / PATOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Urinálise / Eritrócitos Limite: Animals Idioma: En Revista: Vet Clin Pathol Assunto da revista: MEDICINA VETERINARIA / PATOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Itália