Your browser doesn't support javascript.
loading
Rapid screening of polybrominated diphenyl ethers in water by solid-phase microextraction coupled with ultrahigh-resolution mass spectrometry.
Liang, Yuchen; Hu, Wenya; Jia, Changcheng; Wang, Yinghao; Dong, Chenglong; Cai, Yan; Xie, Qingqing; Zhu, Xiaowen; Han, Yehua.
Afiliação
  • Liang Y; State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing, Beijing, 102249, China.
  • Hu W; State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing, Beijing, 102249, China.
  • Jia C; Beijing 101 Eco-Geology Detection Co., Ltd, Beijing Institute of Geological Engineering Design, Beijing, 101500, China.
  • Wang Y; State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing, Beijing, 102249, China.
  • Dong C; State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing, Beijing, 102249, China.
  • Cai Y; Beijing 101 Eco-Geology Detection Co., Ltd, Beijing Institute of Geological Engineering Design, Beijing, 101500, China.
  • Xie Q; State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing, Beijing, 102249, China.
  • Zhu X; State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing, Beijing, 102249, China.
  • Han Y; State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing, Beijing, 102249, China. hanyehua@cup.edu.cn.
Anal Bioanal Chem ; 415(8): 1437-1444, 2023 Mar.
Article em En | MEDLINE | ID: mdl-36648546
ABSTRACT
Polybrominated diphenyl ethers (PBDEs) are considered emerging organic contaminants that attract more attention in the environment. Herein, online coupling of solid-phase microextraction and ultrahigh-resolution mass spectrometry was developed for rapid screening of eight PBDEs in water samples. This procedure was completed in 22 min, about 6 times faster than the routine workflow such as solid-phase extraction coupled with gas chromatography-mass spectrometry. Thermal desorption and solvent-assisted atmospheric pressure chemical ionization were developed for the effective coupling of solid-phase microextraction (SPME) with ultrahigh-resolution mass spectrometry (UHRMS), which contributed to the signal enhancement and made the methodology feasible for environmental screening. The limits of detection and quantification were 0.01-0.50 ng/mL and 0.05-4.00 ng/mL, respectively. The recoveries were 57.2-75.2% for quality control samples at spiking levels of 0.8-10 ng/mL (4-50 ng/mL for BDE209), with relative standard deviation less than 19.0%. Twelve water samples from different river sites near industrial areas were screened using the developed method. The results showed that BDE-209 was the dominant PBDE (1.02-1.28 ng/mL in positive samples), but its amount was lower than the human health ambient water quality criteria. Consequently, the developed method provides a rapid and reliable way of evaluating contamination status and risks of PBDEs in aqueous environment.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China