Residual motion of different posterior instrumentation and interbody fusion constructs.
Burkhard, Marco D; Spirig, José M; Wanivenhaus, Florian; Cornaz, Frédéric; Fasser, Marie-Rosa; Widmer, Jonas; Farshad, Mazda.
Afiliação
  • Burkhard MD; Department of Orthopedic Surgery, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland. marco.burkhard@balgrist.ch.
  • Spirig JM; Department of Orthopedic Surgery, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
  • Wanivenhaus F; Department of Orthopedic Surgery, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
  • Cornaz F; Department of Orthopedic Surgery, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland.
  • Fasser MR; Institute for Biomechanics, Balgrist Campus, ETH Zurich, Lengghalde 5, CH-8008, Zurich, Switzerland.
  • Widmer J; Spine Biomechanics, Department of Orthopedic Surgery, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
  • Farshad M; Institute for Biomechanics, Balgrist Campus, ETH Zurich, Lengghalde 5, CH-8008, Zurich, Switzerland.
Eur Spine J ; 32(4): 1411-1420, 2023 04.
Article em En | MEDLINE | ID: mdl-36820922
ABSTRACT

PURPOSE:

To elucidate residual motion of cortical screw (CS) and pedicle screw (PS) constructs with unilateral posterior lumbar interbody fusion (ul-PLIF), bilateral PLIF (bl-PLIF), facet-sparing transforaminal lumbar interbody fusion (fs-TLIF), and facet-resecting TLIF (fr-TLIF).

METHODS:

A total of 35 human cadaver lumbar segments were instrumented with PS (n = 18) and CS (n = 17). Range of motion (ROM) and relative ROM changes were recorded in flexion/extension (FE), lateral bending (LB), axial rotation (AR), lateral shear (LS), anterior shear (AS), and axial compression (AC) in five instrumentational states without interbody fusion (wo-IF), ul-PLIF, bl-PLIF, fs-TLIF, and fr-TLIF.

RESULTS:

Whereas FE, LB, AR, and AC noticeably differed between the instrumentational states, AS and LS were less prominently affected. Compared to wo-IF, ul-PLIF caused a significant increase in ROM with PS (FE + 42%, LB + 24%, AR + 34%, and AC + 77%), however, such changes were non-significant with CS. ROM was similar between wo-IF and all other interbody fusion techniques. Insertion of a second PLIF (bl-PLIF) significantly decreased ROM with CS (FE -17%, LB -26%, AR -20%, AC -51%) and PS (FE - 23%, LB - 14%, AR - 20%, AC - 45%,). Facet removal in TLIF significantly increased ROM with CS (FE + 6%, LB + 9%, AR + 17%, AC of + 23%) and PS (FE + 7%, AR + 12%, AC + 13%).

CONCLUSION:

bl-PLIF and TLIF show similarly low residual motion in both PS and CS constructs, but ul-PLIF results in increased motion. The fs-TLIF technique is able to further decrease motion compared to fr-TLIF in both the CS and PS constructs.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fusão Vertebral / Parafusos Pediculares Limite: Humans Idioma: En Revista: Eur Spine J Assunto da revista: ORTOPEDIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fusão Vertebral / Parafusos Pediculares Limite: Humans Idioma: En Revista: Eur Spine J Assunto da revista: ORTOPEDIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Suíça