Your browser doesn't support javascript.
loading
Histological Response to 5 kHz Irreversible Electroporation in a Porcine Liver Model.
Kim, Hong Bae; Baik, Ku Youn; Sung, Chang Kyu.
Afiliação
  • Kim HB; Medical Engineering Research Center, The Standard Co. Ltd, Gunpo-si, Republic of Korea.
  • Baik KY; Electrical and Biological Physics, Kwangwoon University, Seoul, Republic of Korea.
  • Sung CK; Department of Radiology, Seoul National University College of Medicine and Boramae Medical Center, Seoul, Republic of Korea.
Technol Cancer Res Treat ; 22: 15330338231171767, 2023.
Article em En | MEDLINE | ID: mdl-37125478
ABSTRACT
Unlike necrosis by thermal ablation, irreversible electroporation (IRE) is known to induce apoptosis by disrupting plasma membrane integrity with electric pulses while preserving the structure of blood vessels and bile ducts in liver tissue without a heat sink effect. This study aimed to investigate thermal damage and histopathological effects in the porcine liver by high-frequency electric pulses (5 kHz) which is much higher than the widely used 1 Hz. The electric field and thermal distributions of 5 kHz electric pulses were compared with those of 1 Hz in numerical simulations. 5 kHz-IRE was applied on pigs under ultrasound imaging to guide the electrode placement. The animals underwent computed tomography (CT) examination immediately and 1 day after IRE. After CT, IRE-treated tissues were taken and analyzed histologically. CT revealed that hepatic veins were intact for 1-day post-IRE. Histopathologically, the structure of the portal vein was intact, but endothelial cells were partially removed. In addition, the hepatic artery structure from which endothelial cells were removed were not damaged, while the bile duct structure and cholangiocytes were intact. The thermal injury was observed only in the vicinity of the electrodes as simulated in silico. 5 kHz-IRE generated high heat due to its short pulse interval, but the thermal damage was limited to the tissue around the electrodes. The histopathological damage caused by 5 kHz-IRE was close to that caused by 1 Hz-IRE. If a short-time treatment is required for reasons such as anesthesia, high-frequency IRE treatment is worth considering. Our observations will contribute to a better understanding of the IRE phenomena and search for advanced therapeutic conditions.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Células Endoteliais / Fígado Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Technol Cancer Res Treat Assunto da revista: NEOPLASIAS / TERAPEUTICA Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Células Endoteliais / Fígado Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Technol Cancer Res Treat Assunto da revista: NEOPLASIAS / TERAPEUTICA Ano de publicação: 2023 Tipo de documento: Article