Cardiac implantable electronic devices replacements in patients followed by remote monitoring during COVID-19 lockdown.
Russo, Vincenzo; Rapacciuolo, Antonio; Pafundi, Pia Clara; de Divitiis, Marcello; Volpicelli, Mario; Ruocco, Antonio; Rago, Anna; Uran, Carlo; Nappi, Felice; Attena, Emilio; Chianese, Raffaele; Esposito, Francesca; Del Giorno, Giuseppe; D'Andrea, Antonello; Ducceschi, Valentino; Russo, Giovanni; Ammendola, Ernesto; Carbone, Angelo; Covino, Gregorio; Manzo, Gianluca; Montella, Gianna Maria; D'Onofrio, Antonio; Nigro, Gerardo.
Afiliação
  • Russo V; Division of Cardiology, Department of Medical Translational Sciences, University of Campania "Luigi Vanvitelli", Via L. Bianchi, 80131, Naples, Italy.
  • Rapacciuolo A; Division of Cardiology, Department of Advanced Biomedical Sciences, University of Naples Federico II, Via S. Pansini, 80131, Naples, Italy.
  • Pafundi PC; Department of Advanced Medical and Surgical Sciences, University of Campania "Luigi Vanvitelli", Piazza L. Miraglia, 80138, Naples, Italy.
  • de Divitiis M; Division of Cardiology, Pellegrini Hospital, Health Authority Naples 1, Via Portamedina, 80134, Naples, Italy.
  • Volpicelli M; Division of Cardiology, San Giovanni Bosco Hospital, Health Authority Naples 1, Via F.M. Briganti, 80144, Naples, Italy.
  • Ruocco A; Interventional Cardiology and Cardiological Care Unit, Cardarelli Hospital, Via A. Cardarelli, 80131, Naples, Italy.
  • Rago A; Cardiology Unit, AORN dei Colli, Via L. Bianchi, 80131, Naples, Italy.
  • Uran C; Cardiology Unit, San Giuseppe and Melorio Hospital, Santa Maria Capua Vetere, Via Melorio, 81055, Caserta, Italy.
  • Nappi F; Division of Cardiology, Moscati Hospital, Contrada Amoretta, 83100, Avellino, Italy.
  • Attena E; Division of Cardiology, San Giuliano Hospital, Giugliano in Campania, Health Authority Naples 2 North, Via. G. Basile, 80014, Naples, Italy.
  • Chianese R; Division of Cardiolgy, San Leonardo Hospital, Castellammare di Stabia, Health Authority Naples 3 South, Viale Europa, 80053, Naples, Italy.
  • Esposito F; Division of Cardiology, San Giovanni di Dio e Ruggi d'Aragona, Via San Leonardo, 84131 13, Salerno, Italy.
  • Del Giorno G; Cardiology Unit, Maria SS Addolorata, Via M. Pagano, 84025, Eboli, Italy.
  • D'Andrea A; Cardiology Unit, Umberto I Hospital, Via A. de Nicola, 84014, Nocera Inferiore, Italy.
  • Ducceschi V; Division of Cardiology, Pellegrini Hospital, Health Authority Naples 1, Via Portamedina, 80134, Naples, Italy.
  • Russo G; Division of Cardiolgy, San Leonardo Hospital, Castellammare di Stabia, Health Authority Naples 3 South, Viale Europa, 80053, Naples, Italy.
  • Ammendola E; Cardiology Unit, AORN dei Colli, Via L. Bianchi, 80131, Naples, Italy.
  • Carbone A; Cardiology Unit, Maria SS Addolorata, Via M. Pagano, 84025, Eboli, Italy.
  • Covino G; Division of Cardiology, San Giovanni Bosco Hospital, Health Authority Naples 1, Via F.M. Briganti, 80144, Naples, Italy.
  • Manzo G; Cardiology Unit, Umberto I Hospital, Via A. de Nicola, 84014, Nocera Inferiore, Italy.
  • Montella GM; Division of Cardiology, Monaldi Hospital, Via L. Bianchi, 80131, Naples, Italy.
  • D'Onofrio A; Division of Cardiology, Monaldi Hospital, Via L. Bianchi, 80131, Naples, Italy.
  • Nigro G; Division of Cardiology, Department of Medical Translational Sciences, University of Campania "Luigi Vanvitelli", Via L. Bianchi, 80131, Naples, Italy.
Eur Heart J Digit Health ; 2(1): 171-174, 2021 Mar.
Article em En | MEDLINE | ID: mdl-37155653
ABSTRACT

Aims:

Following coronavirus disease (COVID-19) outbreak, the Italian government adopted strict rules of lockdown and social distancing. The aim of our study was to assess the admission rate for cardiac implantable electronic devices (CIEDs) replacement procedures in Campania, the 3rd-most-populous region of Italy, during COVID-19 lockdown. Methods and

results:

Data were sourced from 16 referral hospitals in Campania from 10 March to 4 May 2020 (lockdown period) and during the same period in 2019. We retrospectively evaluated consecutive patients hospitalized for CIEDs replacement procedures during the two observational periods. The number and type of CIEDs replacement procedures among patients followed by remote monitoring (RM), the admission rate, and the type of hospital admission between the two observational periods were compared. In total, 270 consecutive patients were hospitalized for CIEDs replacement procedures over the two observation periods. Overall CIEDs replacement procedures showed a reduction rate of 41.2% during COVID-19 lockdown. Patients were equally distributed for sex (P = 0.581), and both age [median 76 years (IQR 68-83) vs. 79 years (IQR 68-83); P = 0.497]. Cardiac implantable electronic devices replacement procedures in patients followed by RM significantly increased (IR +211%; P < 0.001), mainly driven by the remarkable increase rate trend of both PM (IR +475%; P < 0.001) and implantable cardiac defibrillator replacement procedures (IR +67%, P = 0.01), during COVID-19 lockdown compared with 2019 timeframe.

Conclusions:

We showed a significant increase trend rate of replacement procedures among CIEDs patients followed by RM, suggesting the hypothesis of its increased use to closely monitoring and to optimize the hospital admission time during COVID-19 lockdown.