Your browser doesn't support javascript.
loading
Self-Collection Blood Test for PFASs: Comparing Volumetric Microsamplers with a Traditional Serum Approach.
Carignan, Courtney C; Bauer, Rachel A; Patterson, Andrew; Phomsopha, Thep; Redman, Eric; Stapleton, Heather M; Higgins, Christopher P.
Afiliação
  • Carignan CC; Department Food Science and Human Nutrition, Michigan State University, East Lansing, Michigan 48864, United States.
  • Bauer RA; Department of Pharmacology and Toxicology, Michigan State University, East Lansing, Michigan 48864, United States.
  • Patterson A; Department of Pharmacology and Toxicology, Michigan State University, East Lansing, Michigan 48864, United States.
  • Phomsopha T; Eurofins Environment Testing America, West Sacramento, California 95605, United States.
  • Redman E; Eurofins Environment Testing America, West Sacramento, California 95605, United States.
  • Stapleton HM; Eurofins Environment Testing America, West Sacramento, California 95605, United States.
  • Higgins CP; Nicholas School of the Environment, Duke University, Durham, North Carolina 27708, United States.
Environ Sci Technol ; 57(21): 7950-7957, 2023 05 30.
Article em En | MEDLINE | ID: mdl-37189231
ABSTRACT
A remote sampling approach was developed at Eurofins for quantifying per- and polyfluoroalkyl substances (PFASs) in whole blood samples collected using volumetric absorptive microsamplers (VAMSs), which allow for self-collection of blood using a finger prick. This study compares PFAS exposure measured by self-collection of blood using VAMSs to the standard venous serum approach. Blood samples were collected from participants (n = 53) in a community with prior PFAS drinking water contamination using a venous blood draw as well as participant self-collection using VAMSs. Whole blood from the venous tubes was also loaded onto VAMSs to compare differences in capillary vs venous whole blood PFAS levels. Samples were quantified for PFASs using liquid chromatography tandem mass spectrometry and online solid-phase extraction. PFAS levels in serum were highly correlated with measurements in capillary VAMSs (r ≥ 0.91 and p < 0.05). Serum PFAS levels were generally twofold higher than whole blood, reflecting expected differences in their composition. Of interest, FOSA was detected in whole blood (both venous and capillary VAMSs) but not in serum. Overall, these findings indicate that VAMSs are useful self-collection tools for assessing elevated human exposure to PFASs.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fluorocarbonos / Testes Hematológicos Limite: Humans Idioma: En Revista: Environ Sci Technol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fluorocarbonos / Testes Hematológicos Limite: Humans Idioma: En Revista: Environ Sci Technol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos