Your browser doesn't support javascript.
loading
Low dose and low dose rate radioluminescence dosimetry.
Bradley, D A; Essa, R Z; Peh, Suat-Cheng; Teow, Sin-Yeang; Chew, Ming-Tsuey; Zubair, H T; Oresegun, Adebiyi; Basaif, Azmi; Choo, Kan Yeep; Ibrahim, Siti A; Abdul-Rashid, Hairul Azhar.
Afiliação
  • Bradley DA; Centre for Applied Physics and Radiation Technologies, Sunway University, PJ, Malaysia; School of Mathematics and Physics, University of Surrey, Guildford, GU2 7XH, UK. Electronic address: dbradley@sunway.edu.my.
  • Essa RZ; Department of Medical Sciences, School of Medical and Life Sciences, Sunway University, PJ, Malaysia.
  • Peh SC; Department of Medical Sciences, School of Medical and Life Sciences, Sunway University, PJ, Malaysia.
  • Teow SY; Department of Medical Sciences, School of Medical and Life Sciences, Sunway University, PJ, Malaysia.
  • Chew MT; Centre for Applied Physics and Radiation Technologies, Sunway University, PJ, Malaysia.
  • Zubair HT; Fiber Optics Research Centre, Multimedia University, Cyberjaya, 63100, Jalan Multimedia, Malaysia; Lumisyns Sdn Bhd, Cyberjaya, 63100, Selangor, Malaysia.
  • Oresegun A; Fiber Optics Research Centre, Multimedia University, Cyberjaya, 63100, Jalan Multimedia, Malaysia.
  • Basaif A; Fiber Optics Research Centre, Multimedia University, Cyberjaya, 63100, Jalan Multimedia, Malaysia.
  • Choo KY; Fiber Optics Research Centre, Multimedia University, Cyberjaya, 63100, Jalan Multimedia, Malaysia.
  • Ibrahim SA; Fiber Optics Research Centre, Multimedia University, Cyberjaya, 63100, Jalan Multimedia, Malaysia.
  • Abdul-Rashid HA; Fiber Optics Research Centre, Multimedia University, Cyberjaya, 63100, Jalan Multimedia, Malaysia.
Appl Radiat Isot ; 198: 110875, 2023 Aug.
Article em En | MEDLINE | ID: mdl-37257265
ABSTRACT
Review is provided of a number of low-dose, low dose rate situations that in study require advances in the development of dosimetric facilities. Using a clinical linac set up to provide doses down to the few mGy level, the performance of a real-time radioluminescence system has then been illustrated, accommodating pulsed as well as continuous dose delivery. The system gate times provide for tracking of the pattern of dose delivery, allowing detailed account of dose and dose-rate variations. The system has been tested in both x-ray and electron mode dose delivery.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria Tipo de estudo: Diagnostic_studies Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria Tipo de estudo: Diagnostic_studies Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2023 Tipo de documento: Article