Your browser doesn't support javascript.
loading
Development of a surface plasmon resonance based immunosensor for diclofenac quantification in water.
Herrera-Domínguez, Marcela; Lambert, Alexander S; Morales-Luna, Gesuri; Pisano, Eduardo; Aguilar-Hernandez, Iris; Mahlknecht, Jürgen; Cheng, Quan; Ornelas-Soto, Nancy.
Afiliação
  • Herrera-Domínguez M; Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey, NL, 64849, Mexico.
  • Lambert AS; Department of Chemistry, University of California, Riverside, CA, 92521, USA.
  • Morales-Luna G; Departamento de Física y Matemáticas, Universidad Iberoamericana, Ciudad de Mexico, Prolongación Paseo de La Reforma 880, Ciudad de Mexico, 01219, Mexico.
  • Pisano E; CONACYT - Centro de Investigación en Materiales Avanzados, S.C., Monterrey, Parque PIIT, 66628, Apodaca, Nuevo León, Mexico.
  • Aguilar-Hernandez I; Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey, NL, 64849, Mexico.
  • Mahlknecht J; Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey, NL, 64849, Mexico.
  • Cheng Q; Department of Chemistry, University of California, Riverside, CA, 92521, USA. Electronic address: quan.cheng@ucr.edu.
  • Ornelas-Soto N; Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey, NL, 64849, Mexico. Electronic address: ornel@tec.mx.
Chemosphere ; 336: 139156, 2023 Sep.
Article em En | MEDLINE | ID: mdl-37290514
ABSTRACT
A Surface Plasmon Resonance (SPR) biosensor based on an inhibition immunoassay was developed for the detection of diclofenac (DCF) in aqueous solution. Due to the small size of DCF, an hapten-protein conjugate was produced by coupling DCF to bovine serum albumin (BSA). DCF-BSA conjugate formation was confirmed via MALDI-TOF mass spectrometry. The resulting conjugate was immobilized onto the surface of a sensor fabricated via e-beam deposition of a 2 nm chromium adhesion layer followed by a 50 nm gold layer onto precleaned BK7 glass slides. Immobilization onto the nano thin gold surface was accomplished by covalent amide linkage through a self-assembled monolayer. Samples were composed of a mixture of antibody at a fixed concentration and DCF at different known concentrations in deionized water, causing the inhibition of anti-DCF on the sensor. The DCF-BSA was obtained with a ratio of 3 DCF molecules per BSA. A calibration curve was performed using concentrations between 2 and 32 µg L-1. The curve was fitted using the Boltzmann equation, reaching a limit of detection (LOD) of 3.15 µg L-1 and limit of quantification (LOQ) of 10.52 µg L-1, the inter-day precision was calculated and an RSD value of 1.96% was obtained; and analysis time of 10 min. The developed biosensor is a preliminary approach to the detection of DCF in environmental water samples, and the first SPR biosensor developed for DCF detection using a hapten-protein conjugate.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Ressonância de Plasmônio de Superfície Idioma: En Revista: Chemosphere Ano de publicação: 2023 Tipo de documento: Article País de afiliação: México

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Ressonância de Plasmônio de Superfície Idioma: En Revista: Chemosphere Ano de publicação: 2023 Tipo de documento: Article País de afiliação: México