Your browser doesn't support javascript.
loading
Spontaneous Interconversion between Different Narrowly Defined Shapes of Rotavirus Double-Layered Particles Studied in Real Time by High-Resolution Mobility Analysis.
Fernandez de la Mora, Juan; Almazán, Fernando; Rodríguez, Javier M.
Afiliação
  • Fernandez de la Mora J; Department of Mechanical Engineering and Materials Science, Yale University, 9 Hillhouse Avenue, New Haven, Connecticut 06520-8286, United States.
  • Almazán F; Department of Cellular and Molecular Biology, Centro Nacional de Biotecnología (CNB), CSIC, Darwin 3, 28049 Madrid, Spain.
  • Rodríguez JM; Department of Macromolecular Structures, Centro Nacional de Biotecnología (CNB), CSIC, Darwin 3, 28049 Madrid, Spain.
Anal Chem ; 95(30): 11483-11490, 2023 08 01.
Article em En | MEDLINE | ID: mdl-37463035
Rotavirus double-layered particles (DLPs) are studied in the gas phase with a high-resolution differential mobility analyzer (DMA). DLPs were transferred to 10 mM aqueous ammonium acetate, electrosprayed into the gas phase, converted into primarily singly charged particles, and DMA-analyzed. Up to seven slightly different conformations were resolved, whose apparently random, fast (minutes), and reversible interconversions were followed in real time. They sometimes evolved into just two distinct structures, with periods of one dominating over the other and vice versa. Differences between the DLP structures in solution and in the gas phase are clearly revealed by the smaller DLP diameter found here (60 versus 70 nm). Nevertheless, we argue that the multiple gas-phase conformers observed originate in as many conformations pre-existing in solution. We further hypothesize that these conformers correspond to incomplete DLPs having lost some of the VP6 trimer quintets surrounding each of the 12 5-fold axes. Instances of this peculiar loss have been previously documented by cryoelectron microscopy for the rotavirus Wa strain, as well as via charge detection mass spectrometry for five other rotavirus strains included in the RotaTec vaccine. Evidence of this loss systematically found for all 7 rotavirus types so far studied in aqueous ammonium acetate may be a special feature of this electrolyte.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Rotavirus Idioma: En Revista: Anal Chem Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Rotavirus Idioma: En Revista: Anal Chem Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos