Your browser doesn't support javascript.
loading
The diagnostic value of Doppler Resistive Index in the differential diagnosis of focal liver lesions.
Dong, Yi; Wang, Wen-Ping; Ignee, Andre; Zuo, Dan; Qiu, Yi-Jie; Zhang, Qi; Lu, Xiu-Yun; Chen, Sheng; Dietrich, Christoph Frank.
Afiliação
  • Dong Y; Department of Ultrasound, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
  • Wang WP; Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China.
  • Ignee A; Department of Gastroenterology and Rheumatology, Julius-Spital Würzburg, Würzburg, Germany.
  • Zuo D; Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China.
  • Qiu YJ; Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China.
  • Zhang Q; Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China.
  • Lu XY; Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China.
  • Chen S; Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China.
  • Dietrich CF; Department General Internal Medicine, Hirslanden Clinics Beau-Site, Salem and Permancence, Bern, Switzerland.
J Ultrason ; 23(93): e45-e52, 2023 Jun.
Article em En | MEDLINE | ID: mdl-37520747
ABSTRACT

Aim:

To investigate the diagnostic value of resistance index (RI) in differentiating focal liver lesions. Patients and

methods:

In this retrospective study, a total of 576 patients with histologically confirmed focal liver lesions were included. Each patient underwent B-mode ultrasound examination and color Doppler ultrasound examination. The RI values of different focal liver lesions were recorded and compared.

Results:

The mean RI value of benign lesions was significantly lower than that of malignant lesions (0.54 ± 0.10 vs. 0.71 ± 0.12) (p <0.05). In malignant lesions, the RI value of intrahepatic cholangiocarcinoma was significantly lower than that of hepatocellular carcinoma lesions. Furthermore, in hepatocellular carcinoma lesions, the RI of large lesions (group 4 >10 cm) was significantly lower than that of small lesions (group 1 ≤2 cm, group 2 2-5 cm) (p <0.05). Taken RI of 0.615 as a cutoff value to differentiate malignant and benign lesions, the sensitivity, specificity, positive predictive value and negative predictive value were 82.80%, 81.00%, 81.34% and 82.48%, respectively.

Conclusion:

Color Doppler ultrasound examination is a valuable imaging method in detecting blood flow signal within liver lesions. The RI parameter should be helpful in differentiating malignant and benign liver tumors.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Idioma: En Revista: J Ultrason Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Idioma: En Revista: J Ultrason Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China