Your browser doesn't support javascript.
loading
Toward cell nuclei precision between OCT and H&E images translation using signal-to-noise ratio cycle-consistency.
Liu, Chih-Hao; Fu, Li-Wei; Chen, Homer H; Huang, Sheng-Lung.
Afiliação
  • Liu CH; Graduate Institute of Photonics and Optoelectronics, National Taiwan University, No.1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan. Electronic address: r10941036@ntu.edu.tw.
  • Fu LW; Graduate Institute of Communication Engineering, National Taiwan University, No.1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan. Electronic address: r10942078@ntu.edu.tw.
  • Chen HH; Graduate Institute of Communication Engineering, National Taiwan University, No.1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan; Department of Electrical Engineering, National Taiwan University, No.1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan; Graduate Institute of Networking and Multimedia, Na
  • Huang SL; Graduate Institute of Photonics and Optoelectronics, National Taiwan University, No.1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan; Department of Electrical Engineering, National Taiwan University, No.1, Sec. 4, Roosevelt Road, Taipei, 10617, Taiwan; All Vista Healthcare Center, National Taiwan Un
Comput Methods Programs Biomed ; 242: 107824, 2023 Dec.
Article em En | MEDLINE | ID: mdl-37832427
ABSTRACT
Medical image-to-image translation is often difficult and of limited effectiveness due to the differences in image acquisition mechanisms and the diverse structure of biological tissues. This work presents an unpaired image translation model between in-vivo optical coherence tomography (OCT) and ex-vivo Hematoxylin and eosin (H&E) stained images without the need for image stacking, registration, post-processing, and annotation. The model can generate high-quality and highly accurate virtual medical images, and is robust and bidirectional. Our framework introduces random noise to (1) blur redundant features, (2) defend against self-adversarial attacks, (3) stabilize inverse conversion, and (4) mitigate the impact of OCT speckles. We also demonstrate that our model can be pre-trained and then fine-tuned using images from different OCT systems in just a few epochs. Qualitative and quantitative comparisons with traditional image-to-image translation models show the robustness of our proposed signal-to-noise ratio (SNR) cycle-consistency method.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Processamento de Imagem Assistida por Computador Idioma: En Revista: Comput Methods Programs Biomed Assunto da revista: INFORMATICA MEDICA Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Processamento de Imagem Assistida por Computador Idioma: En Revista: Comput Methods Programs Biomed Assunto da revista: INFORMATICA MEDICA Ano de publicação: 2023 Tipo de documento: Article