Your browser doesn't support javascript.
loading
Postoperative Activity and Knee Function of Patients after Total Knee Arthroplasty: A Sensor-Based Monitoring Study.
Kersten, Sebastian; Prill, Robert; Hakam, Hassan Tarek; Hofmann, Hannes; Kayaalp, Mahmut Enes; Reichmann, Jan; Becker, Roland.
Afiliação
  • Kersten S; Center of Orthopaedics and Traumatology, University Hospital Brandenburg/Havel, Brandenburg Medical School Theodor Fontane, 14770 Brandenburg an der Havel, Germany.
  • Prill R; Department of Orthopaedic Surgery, Sana Kliniken Sommerfeld, 16766 Sommerfeld, Germany.
  • Hakam HT; Center of Orthopaedics and Traumatology, University Hospital Brandenburg/Havel, Brandenburg Medical School Theodor Fontane, 14770 Brandenburg an der Havel, Germany.
  • Hofmann H; Faculty of Health Sciences Brandenburg, Brandenburg Medical School Theodor Fontane, 14770 Brandenburg an der Havel, Germany.
  • Kayaalp ME; Center of Orthopaedics and Traumatology, University Hospital Brandenburg/Havel, Brandenburg Medical School Theodor Fontane, 14770 Brandenburg an der Havel, Germany.
  • Reichmann J; Center of Orthopaedics and Traumatology, University Hospital Brandenburg/Havel, Brandenburg Medical School Theodor Fontane, 14770 Brandenburg an der Havel, Germany.
  • Becker R; Center of Orthopaedics and Traumatology, University Hospital Brandenburg/Havel, Brandenburg Medical School Theodor Fontane, 14770 Brandenburg an der Havel, Germany.
J Pers Med ; 13(12)2023 Nov 21.
Article em En | MEDLINE | ID: mdl-38138855
ABSTRACT
Inertial measurement units (IMUs) are increasingly being used to assess knee function. The aim of the study was to record patients' activity levels and to detect new parameters for knee function in the early postoperative phase after TKA. Twenty patients (n = 20) were prospectively enrolled. Two sensors were attached to the affected leg. The data were recorded from the first day after TKA until discharge. Algorithms were developed for detecting steps, range of motion, horizontal, sitting and standing postures, as well as physical therapy. The mean number of steps increased from day 1 to discharge from 117.4 (SD ± 110.5) to 858.7 (SD ± 320.1), respectively. Patients' percentage of immobilization during daytime (6 a.m. to 8 p.m.) was 91.2% on day one and still 69.9% on the last day. Patients received daily continuous passive motion therapy (CPM) for a mean of 36.4 min (SD ± 8.2). The mean angular velocity at day 1 was 12.2 degrees per second (SD ± 4.4) and increased to 28.7 (SD ± 16.4) at discharge. This study shows that IMUs monitor patients' activity postoperatively well, and a wide range of interindividual motion patterns was observed. These sensors may allow the adjustment of physical exercise programs according to the patient's individual needs.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Pers Med Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Pers Med Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha