Relapse and failure rates between CAD/CAM and conventional fixed retainers: a 2-year follow-up of a randomized controlled clinical trial.
Eur J Orthod
; 46(1)2024 Jan 01.
Article
em En
| MEDLINE
| ID: mdl-38168815
ABSTRACT
BACKGROUND:
Retention has been always considered a major challenge in orthodontics. Recently computer-aided design/computer-aided manufacturing (CAD/CAM) fixed retainers (FRs) have been introduced as a marked development in retainer technology, offering potential advantages.OBJECTIVE:
The objective of this study was to compare the differences in relapse and failure rates in patients treated with FRs using CAD/CAM technology, lab-based technique, and chairside method. TRIALDESIGN:
A double-blinded, prospective, randomized controlled clinical trial was conducted over a 2-year period at a single centre.INTERVENTIONS:
These patients were divided into three groups CAD/CAM group with multistranded Stainless Steel wires (CAD/CAM, nâ =â 14), lab group with the same multistranded wires (lab, nâ =â 15), and a chairside group with Stainless Steel Ortho-FlexTech wires (chairside, nâ =â 14).OUTCOMES:
Inter-canine width (ICW) and Little's irregularity index were digitally measured from scans at the orthodontic debonding (T1), 6-month retention (T2), 1-year retention (T3), and 2-year retention (T4) visits. All forms of failure were documented and analyzed. RANDOMIZATION Participants were randomly assigned to the three groups using online randomization software (randomization.com) by a statistician who was not involved in the study. BLINDING Patients were blinded in terms of the FR group to which they were each randomly assigned. The principal investigator was blinded upon data analysis since patients' records were coded to minimize observer and measurement bias.RESULTS:
Initially 81 patients were assessed for eligibility. Seventy-five patients were randomly allocated into the three study groups. After 2-year follow-up, 43 patients came back for the follow-up and were analyzed. The CAD/CAM group showed significantly less reduction in ICW compared to the chairside group at all time intervals (Pâ <â .05) and compared to the lab group at 6 months (Pâ =â .038). In terms of LII, the CAD/CAM group exhibited significantly less change than the chairside and lab groups at all time intervals (Pâ <â .05). The CAD/CAM group had the lowest failure rate (21.4%), followed by chairside group (28.6%) and then lab group (33.3%), however the differences were insignificant. No harms were observed in the current study.CONCLUSION:
Within 2 years of fixed retention, CAD/CAM FRs showed significantly less relapse than lab-based and chairside FRs. However, there was no significant difference in failure rates among the groups. TRIAL REGISTRATION NCT05915273.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Aço Inoxidável
/
Desenho de Aparelho Ortodôntico
Tipo de estudo:
Clinical_trials
/
Observational_studies
/
Prognostic_studies
Limite:
Humans
Idioma:
En
Revista:
Eur J Orthod
/
Eur. j. orthod
/
European journal of orthodontics
Ano de publicação:
2024
Tipo de documento:
Article
País de afiliação:
Estados Unidos