Your browser doesn't support javascript.
loading
A flexible open-source processing workflow for multiplexed fluorescence imaging based on cycles.
Potier, Guillaume; Doméné, Aurélie; Paul-Gilloteaux, Perrine.
Afiliação
  • Potier G; Nantes Université, Inserm UMR 1307, CNRS UMR 6075, Université d'Angers, CRCI2NA, Nantes, F-44000, France.
  • Doméné A; LabEx IGO "Immunotherapy, Graft, Oncology", Nantes, France.
  • Paul-Gilloteaux P; Nantes Université, Inserm UMR 1307, CNRS UMR 6075, Université d'Angers, CRCI2NA, Nantes, F-44000, France.
F1000Res ; 11: 1121, 2022.
Article em En | MEDLINE | ID: mdl-38249121
ABSTRACT
Background  Multiplexing tissue imaging is developing as a complement for single cell analysis, bringing the spatial information of cells in tissue in addition to multiple parameters measurements. More and more commercial or home-made systems are available. These techniques allow the imaging of tens of fluorescent reporters, where the spectral overlap is solved by imaging by cycles the fluorophores using microfluidics to change the reporters between each cycle. Methods  For several systems, the acquisition system coupled to the microfluidic system is a wide field microscope, and the acquisition process is done by mosaicking to cover a large field of view, relying on image processing to obtain the data set to be analysed in intensity. The processed data set allows the identification of different populations, quite similarly to cytometry analysis, but with spatial information in addition. To obtain the final image for analysis from the raw acquisitions, several preprocessing steps are needed for inter-cycle registration, tissue autofluorescence correction or mosaicking. We propose a workflow for this preprocessing, implemented as an open source software (as a library, command line tool and standalone). Results  We exemplify the workflow on the commercial system PhenoCycler TM (formerly named CODEX®) and provide a reduced size data set for testing. Conclusions  We compare our processor with the commercially provided processor and show that we solve some problems also reported by other users.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tetranitrato de Pentaeritritol / Imagem Óptica Idioma: En Revista: F1000Res Ano de publicação: 2022 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tetranitrato de Pentaeritritol / Imagem Óptica Idioma: En Revista: F1000Res Ano de publicação: 2022 Tipo de documento: Article País de afiliação: França