Your browser doesn't support javascript.
loading
Bond strength comparison of a fiber-reinforced composite resin: Different dentin conditions and preparation techniques.
Agaccioglu, Merve; Sirin Karaarslan, Emine; Aytac Bal, Fatma; Benli, Ismail.
Afiliação
  • Agaccioglu M; Department of Restorative Dentistry, Faculty of Dentistry, Bolu Abant Izzet Baysal University, Bolu, Turkey.
  • Sirin Karaarslan E; Department of Restorative Dentistry, Faculty of Dentistry, Tokat Gaziosmanpasa University, Tokat, Turkey.
  • Aytac Bal F; Department of Restorative Dentistry, Faculty of Dentistry, Biruni University, Istanbul, Turkey.
  • Benli I; Laboratory Specialist, Sugenomics Biotechnology, Ankara, Turkey.
Microsc Res Tech ; 87(6): 1250-1261, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38339919
ABSTRACT
This study aimed to compare the bond strength of a fiber-reinforced composite resin with traditional and bulk-fill composite resins under different dentin conditions and preparation techniques. Eighty molar teeth, excluding the mesio-distal half of the occlusal dentin surfaces of each teeth, were isolated with acid-resistant nail varnish and stored in a demineralisation solution (pH 4.5). After mechanical removal of the varnish, the teeth were buried in acrylic resin blocks. In every composite resin group, one-half of the specimens were prepared with a diamond bur and another half with Er YAG laser. Then, the specimens were divided into four groups of composite resins (Filtek Z250, G-aenial Posterior, SonicFill 2, Ever X Posterior) (n = 10). Shear bond strengths were measured using a universal testing device, and failure types were determined with stereomicroscope images. SEM images were obtained at 1000× magnification. Data were analyzed using a three-way analysis of variance (ANOVA), and Bonferroni correction was used for multiple comparisons (p = .05). Differences in the dentin surface affected the bond strength results (p < .05), whereas there was no significant difference between cavity preparation methods (p > .05). EverX Posterior showed the highest bond strength results. Within the limitations of this study, fiber-reinforced composite resin exhibited successful bond strength results in addition to improved mechanical properties. RESEARCH HIGHLIGHTS Fiber-reinforced composite had successful bond strength values. Bond strength values of sound dentin groups were higher than those of caries-affected dentin groups. The use of an Er YAG laser for preparation did not lead to insufficient bond strength results.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Colagem Dentária / Lasers de Estado Sólido Idioma: En Revista: Microsc Res Tech / Microsc. res. tech / Microscopy research and technique Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Turquia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Colagem Dentária / Lasers de Estado Sólido Idioma: En Revista: Microsc Res Tech / Microsc. res. tech / Microscopy research and technique Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Turquia