Your browser doesn't support javascript.
loading
Assessment of arterial pulsatility of cerebral perforating arteries using 7T high-resolution dual-VENC phase-contrast MRI.
Tang, Jianing; Heidari Pahlavian, Soroush; Joe, Elizabeth; Gamez, Maria Tereza; Zhao, Tianrui; Ma, Samantha J; Jin, Jin; Cen, Steven Yong; Chui, Helena C; Yan, Lirong.
Afiliação
  • Tang J; Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.
  • Heidari Pahlavian S; Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA.
  • Joe E; USC Mark and Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.
  • Gamez MT; Department of Neurology, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.
  • Zhao T; Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.
  • Ma SJ; Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.
  • Jin J; Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA.
  • Cen SY; USC Mark and Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.
  • Chui HC; Siemens Medical Solutions USA, Los Angeles, California, USA.
  • Yan L; USC Mark and Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.
Magn Reson Med ; 92(2): 605-617, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38440807
ABSTRACT

PURPOSE:

Directly imaging the function of cerebral perforating arteries could provide valuable insight into the pathology of cerebral small vessel diseases (cSVD). Arterial pulsatility has been identified as a useful biomarker for assessing vascular dysfunction. In this study, we investigate the feasibility and reliability of using dual velocity encoding (VENC) phase-contrast MRI (PC-MRI) to measure the pulsatility of cerebral perforating arteries at 7 T.

METHODS:

Twenty participants, including 12 young volunteers and 8 elder adults, underwent high-resolution 2D PC-MRI scans with VENCs of 20 cm/s and 40 cm/s at 7T. The sensitivity of perforator detection and the reliability of pulsatility measurement of cerebral perforating arteries using dual-VENC PC-MRI were evaluated by comparison with the single-VENC data. The effects of temporal resolution in the PC-MRI acquisition and aging on the pulsatility measurements were investigated.

RESULTS:

Compared to the single VENCs, dual-VENC PC-MRI provided improved sensitivity of perforator detection and more reliable pulsatility measurements. Temporal resolution impacted the pulsatility measurements, as decreasing temporal resolution led to an underestimation of pulsatility. Elderly adults had elevated pulsatility in cerebral perforating arteries compared to young adults, but there was no difference in the number of detected perforators between the two age groups.

CONCLUSION:

Dual-VENC PC-MRI is a reliable imaging method for the assessment of pulsatility of cerebral perforating arteries, which could be useful as a potential imaging biomarker of aging and cSVD.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fluxo Pulsátil / Imageamento por Ressonância Magnética / Artérias Cerebrais Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fluxo Pulsátil / Imageamento por Ressonância Magnética / Artérias Cerebrais Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos