Your browser doesn't support javascript.
loading
Determination of sulfonamide antibiotics by magnetic porous carbon solid-phase extraction coupled with capillary electrophoresis.
Zhang, Maosen; Yang, Hanyu; Yang, Kaijing; Yang, Qiang; Liu, Wei; Yang, Xiupei.
Afiliação
  • Zhang M; College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, 637000, PR China.
  • Yang H; College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, 637000, PR China.
  • Yang K; College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, 637000, PR China.
  • Yang Q; College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, 637000, PR China.
  • Liu W; College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, 637000, PR China. Electronic address: weiliu2022@cwnu.edu.cn.
  • Yang X; College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong, 637000, PR China. Electronic address: xiupeiyang@cwnu.edu.cn.
J Chromatogr A ; 1725: 464926, 2024 Jun 21.
Article em En | MEDLINE | ID: mdl-38678693
ABSTRACT
Sulfonamide antibiotics (SAs) have been widely used as antibacterial drugs for the prevention and treatment of livestock and poultry diseases, but they seriously threaten human health because they can accumulate in humans. Therefore, it is highly important to develop methods for monitoring sulfonamide residues in aquaculture and food. In this research, based on the generation of porous carbon (PC) by the pyrolysis of sodium citrate, magnetic porous carbon (PC@Fe3O4) was synthesized by a solvothermal method and used as an adsorbent for the magnetic solid-phase extraction of SAs. The effects of the proportion of PC in PC@Fe3O4, adsorbent dosage, adsorption time, eluent type, extraction pH, salt concentration and eluent dosage on the extraction efficiency were systematically studied. The adsorption performance and behavior of PC@Fe3O4 on SAs were evaluated using adsorption kinetics and adsorption isotherms, and the adsorption mechanism was preliminarily discussed. Under optimal conditions, combined with capillary electrophoresis diode array detection, a sensitive detection method for SAs was developed. The proposed method can be used for the determination of six SAs in fishpond water and milk samples, with a linear range of 0.5-200 ng mL-1, detection limits of 0.24-0.34 ng mL-1, and spiked recoveries of 85.9-109.0 %.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sulfonamidas / Carbono / Eletroforese Capilar / Leite / Extração em Fase Sólida / Limite de Detecção / Antibacterianos Limite: Animals Idioma: En Revista: J Chromatogr A Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sulfonamidas / Carbono / Eletroforese Capilar / Leite / Extração em Fase Sólida / Limite de Detecção / Antibacterianos Limite: Animals Idioma: En Revista: J Chromatogr A Ano de publicação: 2024 Tipo de documento: Article