Your browser doesn't support javascript.
loading
Stent sizing by coronary CT angiography compared with optical coherence tomography.
Ko, Brian; Ohashi, Hirofumi; Mizukami, Takuya; Sakai, Koshiro; Sonck, Jeroen; Nørgaard, Bjarne Linde; Maeng, Michael; Jensen, Jesper Møller; Ihdayhid, Abdul; Tajima, Atomu; Ando, Hirohiko; Amano, Tetsuya; De Bruyne, Bernard; Koo, Bon-Kwon; Otake, Hiromasa; Collet, Carlos.
Afiliação
  • Ko B; Monash Cardiovascular Research Centre, Monash University and Monash Heart, Monash Health, Clayton, Victoria, Australia.
  • Ohashi H; Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium; Department of Cardiology, Aichi Medical University, Aichi, Japan.
  • Mizukami T; Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium; Division of Clinical Pharmacology, Department of Pharmacology, Showa University, Tokyo, Japan; Department of Cardiovascular Medicine, Gifu Heart Center, Japan.
  • Sakai K; Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium; Department of Medicine, Division of Cardiology, Showa University School of Medicine, Tokyo, Japan.
  • Sonck J; Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium.
  • Nørgaard BL; Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark; Department Clinical Medicine, Aarhus University, Aarhus, Denmark.
  • Maeng M; Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark; Department Clinical Medicine, Aarhus University, Aarhus, Denmark.
  • Jensen JM; Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark.
  • Ihdayhid A; Fiona Stanley Hospital, Perth, Australia.
  • Tajima A; Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium; Department of Cardiology, Aichi Medical University, Aichi, Japan.
  • Ando H; Department of Cardiology, Aichi Medical University, Aichi, Japan.
  • Amano T; Department of Cardiology, Aichi Medical University, Aichi, Japan.
  • De Bruyne B; Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium; Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland.
  • Koo BK; Department of Internal Medicine and Cardiovascular Center, Seoul National University Hospital, Seoul, South Korea.
  • Otake H; Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.
  • Collet C; Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium. Electronic address: carloscollet@gmail.com.
J Cardiovasc Comput Tomogr ; 18(4): 337-344, 2024.
Article em En | MEDLINE | ID: mdl-38789325
ABSTRACT

BACKGROUND:

Coronary CT angiography (CCTA) is well-established for diagnosis and stratification of coronary artery disease (CAD). Its usefulness in guiding percutaneous coronary interventions (PCI) and stent sizing is unknown.

METHODS:

This is a sub-analysis of the Precise Percutaneous Coronary Intervention Plan (P3) study (NCT03782688). We analyzed 65 vessels with matched CCTA and pre-PCI optical coherence tomography (OCT) assessment. The CCTA-guided stent size was defined by the mean distal reference lumen diameter rounded up to the nearest stent diameter. The OCT lumen-guided stent size was the mean distal reference lumen diameter rounded to the closest stent diameter. The agreement on stent diameters was determined with Kappa statistics, Passing-Bablok regression analysis, and the Bland-Altman method.

RESULTS:

The distal reference lumen diameter by CCTA and OCT were 2.75 â€‹± â€‹0.53 â€‹mm and 2.72 â€‹± â€‹0.55 â€‹mm (mean difference 0.06, limits of agreement -0.7 to 0.82). There were no proportional or systematic differences (coefficient A 1.06, 95% CI 0.84 to 1.3 and coefficient B -0.22, 95% CI -0.83 to 0.36) between methods. The agreement between the CCTA and OCT stent size was substantial (Cohen's weighted Kappa 0.74, 95% CI 0.64 to 0.85). Compared to OCT stent diameter, CCTA stent size was concordant in 52.3% of the cases; CCTA overestimated stent size in 20.0% and underestimated in 27.7%.

CONCLUSION:

CCTA accurately assessed the reference vessel diameter used for stent sizing. CCTA-based stent sizing showed a substantial agreement with OCT. CCTA allows for PCI planning and may aid in selecting stent diameter.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Doença da Artéria Coronariana / Stents / Valor Preditivo dos Testes / Angiografia Coronária / Vasos Coronários / Tomografia de Coerência Óptica / Intervenção Coronária Percutânea / Angiografia por Tomografia Computadorizada Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Comput Tomogr / Journal of cardiovascular computed tomography (Online) Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / RADIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Doença da Artéria Coronariana / Stents / Valor Preditivo dos Testes / Angiografia Coronária / Vasos Coronários / Tomografia de Coerência Óptica / Intervenção Coronária Percutânea / Angiografia por Tomografia Computadorizada Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Comput Tomogr / Journal of cardiovascular computed tomography (Online) Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / RADIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Austrália