Your browser doesn't support javascript.
loading
Interobserver agreement and diagnostic challenges of Congo red staining for amyloid detection on fat pad aspiration biopsies.
Trabzonlu, Levent; Helland, T Leif; Kwan, Melanie C; Kumiega, Nathalie; Zhang, M Lisa; Chebib, Ivan; Torous, Vanda F.
Afiliação
  • Trabzonlu L; Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts.
  • Helland TL; Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts.
  • Kwan MC; Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts.
  • Kumiega N; Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts.
  • Zhang ML; Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts.
  • Chebib I; Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts.
  • Torous VF; Department of Pathology, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts. Electronic address: vtorous@mgh.harvard.edu.
J Am Soc Cytopathol ; 2024 Jun 04.
Article em En | MEDLINE | ID: mdl-38960799
ABSTRACT

INTRODUCTION:

Congo red staining of fat pad fine needle aspiration specimens is a method utilized for evaluation of amyloid deposition. However, these specimens can pose diagnostic challenges for cytopathologists. As part of ongoing internal quality improvement measures, the objective of this study was to evaluate the intradepartmental interobserver agreement of these specimens and to identify factors that affect the variability of the interpretations. MATERIALS AND

METHODS:

There were 7 participants, which included 3 trainees, 3 cytopathologists, and 1 cytotechnologist. Each participant reviewed 50 Congo red stained fat pad fine needle aspiration slides. The interpretations were categorized into 3 groups negative, indeterminate/suspicious, and positive. The participants also noted any interpretation challenges they encountered for each case.

RESULTS:

There was only slight interobserver agreement among all participants (κ = 0.133). Stratified by participant group, the interobserver agreement among the trainees was slight bordering on poor (κ = 0.028) and among cytopathologists was fair (κ = 0.249). The highest agreement between 2 observers was between 2 cytopathologists and the level of agreement was moderate bordering on fair (κ = 0.426). There were only 3 cases (6.0%) with full agreement among observers, while in 25 cases (50.0%), there were 2 category differences in interpretations. The primary diagnostic challenge reported by participants was when weak or focal birefringence was encountered as well as cases complicated by poor stain quality and overstaining.

CONCLUSIONS:

We found only slight interobserver agreement among all study participants. A major area of challenge was cases with weak birefringence resulting in high variance of interpretation among participants.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Am Soc Cytopathol Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Am Soc Cytopathol Ano de publicação: 2024 Tipo de documento: Article