Your browser doesn't support javascript.
loading
Catheter ablation for focal atrial tachycardias during pregnancy: A systematic review.
Ventrella, Nicoletta; Schiavone, Marco; Bianchini, Lorenzo; Sicuso, Rita; Dessanai, Maria Antonietta; Di Biase, Luigi; Tondo, Claudio.
Afiliação
  • Ventrella N; Department of Clinical Electrophysiology & Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy; Department of Clinical Sciences and Community Health, Cardiovascular Section, University of Milan, Milan, Italy. Electronic address: nicoletta.ventrella@unimi.it.
  • Schiavone M; Department of Clinical Electrophysiology & Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Bianchini L; Department of Clinical Electrophysiology & Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Sicuso R; Department of Clinical Electrophysiology & Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Dessanai MA; Department of Clinical Electrophysiology & Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Di Biase L; Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, NY, USA.
  • Tondo C; Department of Clinical Electrophysiology & Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy; Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy.
Int J Cardiol ; : 132333, 2024 Jul 05.
Article em En | MEDLINE | ID: mdl-38972492
ABSTRACT

OBJECTIVE:

Pregnancy can trigger maternal tachycardias, and the onset of recurrent or incessant focal atrial tachycardia (AT) can lead to tachycardia-induced cardiomyopathy. Medical interventions are commonly employed, but they carry potential fetal and maternal risks. Catheter ablation (CA), particularly with non-fluoroscopic navigation systems, may be considered as an alternative. This systematic review aims to explore the feasibility and outcomes of CA for focal AT during pregnancy.

METHODS:

A thorough literature search was conducted until September 30th, 2023, on PubMed, Embase, and Cochrane databases. Included articles described maternal focal ATs diagnosed through electrophysiological studies and treated with CA. Data derived from these studies were organized into tables and subsequently analyzed.

RESULTS:

Out of 278 papers reviewed, 15 articles involving 24 patients were retrieved. CA, utilizing radiofrequency energy achieved acute success in 95.8% of cases. Sixteen patients (66.7%) underwent complete fluoroless procedures, with two adverse events directly related to the procedure reported. Long-term follow-up revealed minimal AT recurrences, with a 0.06% arrhythmia burden in one case.

CONCLUSION:

Focal ATs during pregnancy can be incessant and refractory to medical intervention, precipitating an acute decline in left ventricular ejection fraction. In this setting, CA emerges as an efficacious treatment modality, particularly in cases of tachycardia-induced cardiomyopathies. Whenever feasible, it is advisable to perform these procedures with minimal or no fluoroscopy guidance. Larger studies are needed to establish the safety and the efficacy of CA for focal ATs during pregnancy, as current research consists of case reports or small case series.