Your browser doesn't support javascript.
loading
Ultrasonography in the evaluation of intrauterine transfusion.
Obstet Gynecol ; 53(5): 656-9, 1979 May.
Article em En | MEDLINE | ID: mdl-440681
ABSTRACT
Numerous techniques have been described in the literature to aid the obstetrician in safely and easily performing an intrauterine transfusion. None, however, have addressed themselves to the question of whether the transfused cells actually enter the fetal peritoneal cavity. We have used gray-scale ultrasonography to evaluate this question in 4 patients who had undergone a total of 8 intrauterine transfusions. By scanning the fetal abdomen both before and after the transfusion, we were able to identify the transfused fluid within the fetal abdomen in all cases.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transfusão de Sangue Intrauterina / Ultrassonografia Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Female / Humans / Pregnancy Idioma: En Revista: Obstet Gynecol Ano de publicação: 1979 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transfusão de Sangue Intrauterina / Ultrassonografia Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Female / Humans / Pregnancy Idioma: En Revista: Obstet Gynecol Ano de publicação: 1979 Tipo de documento: Article