Your browser doesn't support javascript.
loading
[The closed system (author's transl)]. / Das geschlossene System.
Anaesthesist ; 26(9): 495-502, 1977 Sep.
Article em De | MEDLINE | ID: mdl-907085
ABSTRACT
It is appropriate to consider dose-regulated or quantitative closed-circuit anesthesia in terms of uptake of inhalation anesthetics from a reservoir bag which is never allowed to fill completely. The method which the authors have used routinely for 8 years requires reduction of the dose as a function of the inverse square root of elapsed anaesthesia time. Nitrogen does not accumulate because there is an inevitable loss of 20 to 100 ml/min between cuff and trachea. A simpler method, which has been well received, is that of "minimal flow" anesthesia (Virtue) with a constant fresh gas flow of 300 ml/min O2 and 200 ml/min N2O. "Low-flow" techniques typically entail use of 500 ml each of O2 and N2O per min.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Anestesia por Inalação Limite: Humans Idioma: De Revista: Anaesthesist Ano de publicação: 1977 Tipo de documento: Article