Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Heart Fail Rev ; 29(2): 479-496, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38112937

RESUMO

Hypertrophic cardiomyopathy (HCM) is the most common heritable myocardial disorder worldwide. Current pharmacological treatment options are limited. Mavacamten, a first-in-class cardiac myosin inhibitor, targets the main underlying pathology of HCM. We conducted a systematic review and meta-analysis to evaluate the efficacy and safety of Mavacamten in patients with HCM. PRISMA flow chart was utilized using PubMed, SCOPUS, and Cochrane databases for all up-to-date studies using pre-defined keywords. Pre-specified efficacy outcomes comprised several parameters, including an improvement in peak oxygen consumption (pVO2) and ≥ 1 NYHA class, the need for septal reduction therapy (SRT), change from baseline in Kansas City Cardiomyopathy Questionnaire (KCCQ), changes in biochemical markers and LVEF, along with peak left ventricular outflow tract gradient at rest and after Valsalva maneuver. Safety outcomes included morbidity and serious adverse events. This systematic review included five studies, four RCTs and one non-randomized control trial comprised a total of 524 (Mavacamten [273, 54.3%] vs placebo [230, 45.7%] adult (≥ 18 years) patients with a mean age of 56 years. The study. comprised patients with Caucasian and Chinese ethnicity and patients with obstructive (oHCM) and non-obstructive (nHCM) HCM. Most baseline characteristics were similar between the treatment and placebo groups. Mavacamten showed a statistically significant increase in the frequency of the primary composite endpoint (RR = 1.92, 95% CI [1.28, 2.88]), ≥ 1 NYHA class improvement (RR = 2.10, 95% CI [1.66, 2.67]), a significant decrease in LVEF, peak left ventricular outflow tract gradient at rest and after Valsalva maneuver. Mavacamten also showed a significant reduction in SRT rates (RR = 0.29, 95% CI [0.21, 0.40], p < 0.00001), KCCQ clinical summary scores (MD = 8.08, 95% CI [4.80, 11.37], P < 0.00001) troponin levels and N-terminal pro-B-type natriuretic peptide levels. However, there was no statistically significant difference between Mavacamten and placebo regarding the change from baseline peak oxygen consumption. Mavacamten use resulted in a small increase in adverse events but no statistically significant increment in serious adverse events. Our study showed that Mavacamten is a safe and effective treatment option for Caucasian and Chinese patients with HCM on the short-term. Further research is needed to explore the long-term safety and efficacy of Mavacamten with HCM. In addition, adequately powered studies including patients with nHCM is needed to ascertain befits of Mavacamten in those patients.


Assuntos
Cardiomiopatia Hipertrófica , Uracila/análogos & derivados , Adulto , Humanos , Pessoa de Meia-Idade , Cardiomiopatia Hipertrófica/tratamento farmacológico , Coração , Benzilaminas/efeitos adversos , Miocárdio
2.
J Neuroophthalmol ; 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38527126

RESUMO

BACKGROUND: To evaluate the quality & reliability, technical quality, and readability of patient-targeted online information on idiopathic intracranial hypertension. METHODS: In this cross-sectional study, we searched Google and Bing search engines for the terms "idiopathic intracranial hypertension" and "pseudotumor cerebri." We evaluated the first 50 search outcomes for each search term. Peer-reviewed articles, targeted advertisements, book chapters, videos, personal blogs, websites intended for healthcare professionals, and non-English websites were excluded. Websites were classified as institutional or private. Two independent reviewers assessed each website for 1) quality and reliability using DISCERN, Health on the Net Code of Conduct (HONcode), and JAMA criteria and 2) technical quality based on 11 criteria. Readability was evaluated using 6 measures (Flesch-Kincaid Reading Ease score and grade level, Gunning Fog, Simple Measure of Gobbledygook (Smog) index, Coleman-Liau index, and automated readability index). RESULTS: Sixty-three websites (37 institutional) were included. The mean scores for the DISCERN, HONcode, and JAMA criteria were 3.6 ± 1 (1-4.8; 1: worse, 5: best), 10.3 ± 2.8 (2-16; 0: worse, 16: best), and 2 ± 1.3 (0-4; 0: worse, 4: best), respectively. The mean technical quality score was 0.8 ± 0.1 (0.5-1). The mean Flesch-Kincaid grade level score was 8.9 ± 1.8 (3.3-13.3). For Flesch-Kincaid grade level, 47 (74.6%) websites scored a grade level of 10 or less. For Gunning Fog Score, 35 websites (55.6%) scored from 7.3 to 10.8. For the Smog Index, 46 (73%) websites scored 5.7-8. The mean Coleman Liau Index was 16 ± 2.1 (9.6-22.2). For the automated readability index, 30 (50.7%) websites scored less than the eighth grade. No statistically significant difference was present between institutional and private websites except for JAMA, which scored higher in private websites (2.4 vs 1.7, P = 0.03). CONCLUSIONS: Our findings suggest that online information on idiopathic intracranial hypertension/pseudotumor cerebri for patients generally demonstrates moderate to good quality and reliability. Although most websites maintain credible technical quality, the readability exceeds recommended levels for the average American reader. This may impede understanding, emphasizing the need for future improvements.

3.
J Pediatr Ophthalmol Strabismus ; 61(3): 198-203, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38112390

RESUMO

PURPOSE: To evaluate the quality, reliability, technical quality, and readability of online information related to childhood glaucoma. METHODS: In this cross-sectional study, no human subjects were studied. Analysis was done for online websites on childhood glaucoma. The terms "childhood glaucoma," "pediatric glaucoma," "congenital glaucoma," "buphthalmos," and "big eyes" were entered into the Google search engine and the first 100 search results were assessed for quality, reliability, technical quality, and readability. Peer-reviewed articles, patient forum posts, dictionary definitions, and websites that appeared as targeted ads, were not in English, or were not focused on humans were excluded. Each website was evaluated for (1) quality and reliability using the DISCERN, HONcode, and JAMA criteria; (2) technical quality assessing 11 technical aspects; and (3) readability using six separate criteria (Flesch-Kincaid Reading Ease Score and Grade Level, Gunning Fog Index score, the Simple Measure of Gobbledygook Index, Coleman-Liau Index, and Automated Readability Index). RESULTS: The median scores for the DISCERN, HONcode, and JAMA criteria were 2.6 (range = 1 to 4.75; 1 = worst, 5 = best), 10 (range = 0 to 16; 0 = worst, 16 = best), and 2 (range = 0 to 4; 0 = worst, 4 = best), respectively. The median technical quality score was 0.7. Readability was poor among most websites, with a median Flesch-Kincaid grade Grade Level Score of 9.3. The median Gunning Fog Index score was 9.8. There was a statistically significantly higher JAMA score and Gunning Fog Index score among the private websites compared to the institutional websites. However, institutional websites had higher technical quality. CONCLUSIONS: Online information on childhood glaucoma had poor to moderate quality and reliability. The technical quality is good; however, most websites' readability was above the recommended 5th to 6th grade reading level. [J Pediatr Ophthalmol Strabismus. 2024;61(3):198-203.].


Assuntos
Compreensão , Glaucoma , Internet , Humanos , Estudos Transversais , Reprodutibilidade dos Testes , Criança , Ferramenta de Busca , Informação de Saúde ao Consumidor/normas
4.
Ann Med Surg (Lond) ; 85(7): 3519-3530, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37427228

RESUMO

Since the declaration of the coronavirus disease 2019 pandemic, all efforts were directed towards limiting the transfer of the disease and preventing severe disease forms from occurring. In this regard, numerous vaccines were quickly developed to limit the associated morbidity and mortality of the disease and to reduce the burden on healthcare systems worldwide. However, to date, vaccine hesitancy remains a major limitation to vaccine distribution, with varying degrees in different countries. Therefore, the authors conducted this literature review to highlight the magnitude of this issue throughout the globe and summarize some of its major causes (i.e. governmental, healthcare system-related, population-related, and vaccine-related) and contributing factors (i.e. knowledge/awareness, social media, etc.). In addition, the authors highlighted some of the main motivating factors that can minimize the burden of vaccine hesitancy at the population, governmental, and worldwide levels. These include structural (i.e. government, country), extrinsic (i.e. family, friends), intrinsic (i.e. self-perception), and other factors (financial and nonfinancial). Finally, the authors proposed some implications for future research to ease the vaccination process and hopefully, put an end to this problem.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA