Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Sci Rep ; 12(1): 6876, 2022 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-35477961

RESUMO

High energy density physics is the field of physics dedicated to the study of matter and plasmas in extreme conditions of temperature, densities and pressures. It encompasses multiple disciplines such as material science, planetary science, laboratory and astrophysical plasma science. For the latter, high energy density states can be accompanied by extreme radiation environments and super-strong magnetic fields. The creation of high energy density states in the laboratory consists in concentrating/depositing large amounts of energy in a reduced mass, typically solid material sample or dense plasma, over a time shorter than the typical timescales of heat conduction and hydrodynamic expansion. Laser-generated, high current-density ion beams constitute an important tool for the creation of high energy density states in the laboratory. Focusing plasma devices, such as cone-targets are necessary in order to focus and direct these intense beams towards the heating sample or dense plasma, while protecting the proton generation foil from the harsh environments typical of an integrated high-power laser experiment. A full understanding of the ion beam dynamics in focusing devices is therefore necessary in order to properly design and interpret the numerous experiments in the field. In this work, we report a detailed investigation of large-scale, kilojoule-class laser-generated ion beam dynamics in focusing devices and we demonstrate that high-brilliance ion beams compress magnetic fields to amplitudes exceeding tens of kilo-Tesla, which in turn play a dominant role in the focusing process, resulting either in a worsening or enhancement of focusing capabilities depending on the target geometry.

2.
Nat Commun ; 10(1): 2995, 2019 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-31278266

RESUMO

Increasing the laser energy absorption into energetic particle beams represents a longstanding quest in intense laser-plasma physics. During the interaction with matter, part of the laser energy is converted into relativistic electron beams, which are the origin of secondary sources of energetic ions, γ-rays and neutrons. Here we experimentally demonstrate that using multiple coherent laser beamlets spatially and temporally overlapped, thus producing an interference pattern in the laser focus, significantly improves the laser energy conversion efficiency into hot electrons, compared to one beam with the same energy and nominal intensity as the four beamlets combined. Two-dimensional particle-in-cell simulations support the experimental results, suggesting that beamlet interference pattern induces a periodical shaping of the critical density, ultimately playing a key-role in enhancing the laser-to-electron energy conversion efficiency. This method is rather insensitive to laser pulse contrast and duration, making this approach robust and suitable to many existing facilities.

3.
Rev Sci Instrum ; 88(7): 075103, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28764534

RESUMO

Infrared (IR) heating processes have been studied to form a deuterium layer in an inertial confinement fusion target. To understand the relationship between the IR intensity and the fuel layering time constant, we have developed a new method to assess the IR intensity during irradiation. In our method, a glass flask acting as a dummy target is filled with liquid hydrogen (LH2) and is then irradiated with 2-µm light. The IR intensity is subsequently calculated from the time constant of the LH2 evaporation rate. Although LH2 evaporation is also caused by the heat inflow from the surroundings and by the background heat, the evaporation rate due to IR heating can be accurately determined by acquiring the time constant with and without irradiation. The experimentally measured IR intensity is 0.66 mW/cm2, which agrees well with a value estimated by considering the IR photon energy balance. Our results suggest that the present method can be used to measure the IR intensity inside a cryogenic system during IR irradiation of laser fusion targets.

4.
Sci Rep ; 7: 42451, 2017 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-28211913

RESUMO

Using one of the world most powerful laser facility, we demonstrate for the first time that high-contrast multi-picosecond pulses are advantageous for proton acceleration. By extending the pulse duration from 1.5 to 6 ps with fixed laser intensity of 1018 W cm-2, the maximum proton energy is improved more than twice (from 13 to 33 MeV). At the same time, laser-energy conversion efficiency into the MeV protons is enhanced with an order of magnitude, achieving 5% for protons above 6 MeV with the 6 ps pulse duration. The proton energies observed are discussed using a plasma expansion model newly developed that takes the electron temperature evolution beyond the ponderomotive energy in the over picoseconds interaction into account. The present results are quite encouraging for realizing ion-driven fast ignition and novel ion beamlines.

5.
Arch Intern Med ; 144(1): 152-4, 1984 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-6362595

RESUMO

A 53-year-old woman with nephroptosis and aortitis disease was found also to have orthostatic hypertension. When standing, she had high renin levels and normal catecholamine values, with a reduced baroreflex sensitivity. This orthostatic hypertension largely may be due to an activation of the renin system caused by nephroptosis and partly due to a reduced baroreflex sensitivity caused by aortitis. Captopril and propranolol hydrochloride were effective for the treatment of hypertension.


Assuntos
Aortite/complicações , Hipertensão/etiologia , Rim/anormalidades , Postura , Captopril/administração & dosagem , Quimioterapia Combinada , Feminino , Humanos , Hipertensão/tratamento farmacológico , Pessoa de Meia-Idade , Pressorreceptores/fisiopatologia , Propranolol/administração & dosagem , Renina/sangue
6.
Rev Sci Instrum ; 86(5): 053503, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26026521

RESUMO

A neutron bang time and burn history monitor in inertial confinement fusion with fast ignition are necessary for plasma diagnostics. In the FIREX project, however, no detector attained those capabilities because high-intensity X-rays accompanied fast electrons used for plasma heating. To solve this problem, single-crystal CVD diamond was grown and fabricated into a radiation detector. The detector, which had excellent charge transportation property, was tested to obtain a response function for intense X-rays. The applicability for neutron bang time and burn history monitor was verified experimentally. Charge collection efficiency of 99.5% ± 0.8% and 97.1% ± 1.4% for holes and electrons were obtained using 5.486 MeV alpha particles. The drift velocity at electric field which saturates charge collection efficiency was 1.1 ± 0.4 × 10(7) cm/s and 1.0 ± 0.3 × 10(7) cm/s for holes and electrons. Fast response of several ns pulse width for intense X-ray was obtained at the GEKKO XII experiment, which is sufficiently fast for ToF measurements to obtain a neutron signal separately from X-rays. Based on these results, we confirmed that the single-crystal CVD diamond detector obtained neutron signal with good S/N under ion temperature 0.5-1 keV and neutron yield of more than 10(9) neutrons/shot.

7.
Phys Rev Lett ; 84(23): 5331-4, 2000 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-10990936

RESUMO

We report experimental results on hydrodynamic perturbation transfer from the rear to the front of laser-irradiated targets. Flat polystyrene foils with rear-surface perturbations were irradiated by partially coherent light. We observed phase inversion of the rear surface after the shock breakout at the rear surface. Perturbations on the laser-irradiated surface arose due to the rippled rarefaction wave. Experimental results were well reproduced by a simple model with unperturbed hydrodynamic quantities calculated from the one-dimensional simulation.

8.
Phys Rev E Stat Nonlin Soft Matter Phys ; 65(4 Pt 2A): 045401, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12005913

RESUMO

We present experimental results on the perturbation transfer of laser irradiated planar foils. Perturbed polystyrene foils were irradiated directly by laser at intensity of 6 x 10(13) W/cm(2). We measured perturbations on the foils by side-on x-ray backlighting technique. Perturbations on the rear surface due to the rippled shock front were observed just after the shock breakout. We also observed feed-through of perturbations on the laser-irradiated surface that grows due to the Rayleigh-Taylor instability.

9.
Rev Sci Instrum ; 85(11): 11D629, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430205

RESUMO

A photonuclear-reaction-based hard x-ray spectrometer is developed to measure the number and energy spectrum of fast electrons generated by interactions between plasma and intense laser light. In this spectrometer, x-rays are converted to neutrons through photonuclear reactions, and the neutrons are counted with a bubble detector that is insensitive to x-rays. The spectrometer consists of a bundle of hard x-ray detectors that respond to different photon-energy ranges. Proof-of-principle experiment was performed on a linear accelerator facility. A quasi-monoenergetic electron bunch (Ne = 1.0 × 10(-6) C, Ee = 16 ± 0.32 MeV) was injected into a 5-mm-thick lead plate. Bremsstrahlung x-rays, which emanate from the lead plate, were measured with the spectrometer. The measured spectral shape and intensity agree fairly well with those computed with a Monte Carlo simulation code. The result shows that high-energy x-rays can be measured absolutely with a photon-counting accuracy of 50%-70% in the energy range from 2 MeV to 20 MeV with a spectral resolution (Δhν/hν) of about 15%. Quantum efficiency of this spectrometer was designed to be 10(-7), 10(-4), 10(-5), respectively, for 2-10, 11-15, and 15-25 MeV of photon energy ranges.

10.
Rev Sci Instrum ; 85(11): 11E125, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430304

RESUMO

A multichannel low-energy neutron spectrometer for down-scattered neutron (DSN) measurements in inertial confinement fusion (ICF) experiments has been developed. Our compact-size 256-channel lithium-glass-scintillator-based spectrometer has been implemented and tested in ICF experiments with the GEKKO XII laser. We have performed time calibration of the 256-channel analog-to-digital convertor system used for DSN measurements via X-ray pulse signals. We have clearly observed the DD-primary fusion neutron signal and have successfully studied the detector's impulse response. Our detector is soon to be implemented in future ICF experiments.

11.
Rev Sci Instrum ; 85(11): 11E126, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430305

RESUMO

The characteristics of oxygen-enriched liquid scintillators with very low afterglow are investigated and optimized for application to a single-hit neutron spectrometer for fast ignition experiments. It is found that 1,2,4-trimethylbenzene has better characteristics as a liquid scintillator solvent than the conventional solvent, p-xylene. In addition, a benzophenon-doped BBQ liquid scintillator is shown to demonstrate very rapid time response, and therefore has potential for further use in neutron diagnostics with fast time resolution.

12.
Rev Sci Instrum ; 83(10): 10D909, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126912

RESUMO

In the fast-ignition scheme, very hard x-rays (hereinafter referred to as γ-rays) are generated by Bremsstrahlung radiation from fast electrons. Significant backgrounds were observed around the deuterium-deuterium fusion neutron signals in the experiment in 2010. In this paper the backgrounds were studied in detail, based on Monte Carlo simulations, and they were confirmed to be γ-rays from the target, scattered γ-rays from the experimental bay walls (γ'-rays), and neutrons generated by (γ, n) reactions in either the target vacuum chamber or the diagnostic instruments (γ-n neutrons).

13.
Rev Sci Instrum ; 83(10): 10E529, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23127036

RESUMO

Developments in measuring sound velocity of matter under ultrahigh pressure are described. We employed a time-resolved x-ray shadowgraph technique to measure the sound velocity of shock-compressed diamond and iron foils at around melt. The sound velocity significantly dropped at melting, a behavior that has been difficult to clarify by conventional measurements by subtracting particle velocity from shock velocity (u(s) - u(p)). In addition to sound velocity, other important parameters were also obtained simultaneously.

14.
Rev Sci Instrum ; 83(5): 053502, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22667617

RESUMO

X-ray line spectra ranging from 17 to 77 keV were quantitatively measured with a Laue spectrometer, composed of a cylindrically curved crystal and a detector. Either a visible CCD detector coupled with a CsI phosphor screen or an imaging plate can be chosen, depending on the signal intensities and exposure times. The absolute sensitivity of the spectrometer system was calibrated using pre-characterized laser-produced x-ray sources and radioisotopes. The integrated reflectivity for the crystal is in good agreement with predictions by an open code for x-ray diffraction. The energy transfer efficiency from incident laser beams to hot electrons, as the energy transfer agency for specific x-ray line emissions, is derived as a consequence of this work.

15.
Rev Sci Instrum ; 81(10): 10D303, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033829

RESUMO

A custom developed (6)Li glass scintillator (APLF80+3Pr) for down-scattered neutron diagnostics in inertial confinement fusion experiments is presented. (6)Li provides an enhanced sensitivity for down-scattered neutrons in DD fusion and its experimentally observed 5-6 ns response time fulfills the requirement for down-scattered neutron detectors. A time-of-flight detector operating in the current mode using the APLF80+3Pr was designed and its feasibility observing down-scattered neutrons was demonstrated. Furthermore, a prototype design for a down-scattered neutron imaging detector was also demonstrated. This material promises viability as a future down-scattered neutron detector for the National Ignition Facility.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA